Welcome! Please use the navigational links to explore our website.
PartsASAP LogoCompany Logo (800) 853-2651

Shop Now

   Allis Chalmers Case Farmall IH Ford 8N,9N,2N Ford
   Ferguson John Deere Massey Ferguson Minn. Moline Oliver
 
Marketplace
Classified Ads
Photo Ads
Tractor Parts
Salvage

Community
Discussion Forums
Project Journals
Your Stories
Events Calendar
Hauling Schedule

Galleries
Tractor Photos
Implement Photos
Vintage Photos
Help Identify
Parts & Pieces
Stuck & Troubled
Vintage Ads
Community Album
Photo Ad Archives

Research & Info
Articles
Tractor Registry
Tip of the Day
Safety Cartoons
Tractor Values
Serial Numbers
Tune-Up Guide
Paint Codes
List Prices
Production Nbrs
Tune-Up Specs
Torque Values
3-Point Specs
Glossary

Miscellaneous
Tractor Games
Just For Kids
Virtual Show
Museum Guide
Memorial Page
Feedback Form

Yesterday's Tractors Facebook Page

  
Tractor Talk Discussion Board

Deere 1010 gas Pertonix starting problem (long/boring)


[ Expand ] [ View Replies ] [ Add a Reply ] [ Return to Forum ]

Posted by LJD on April 27, 2012 at 06:09:35 from (75.213.222.173):

I feel kind of silly posting this since I've been working on these things for near 50 years. But -just the same I'm curious if anyone else with a 1010 has had this problem. I'm at the point where I may just start changing parts to see if something works.

I've had this 1010 crawler loader for 15-20 years. It's always been a poor starter in cold weather below 30 degrees F, but otherwise it's been fine. Once running - it runs absolutely perfect. I rebuilt the engine when I first got it, mainly because it had been in a fire. Distributor was melted and I had to buy a used Delco. Ran it for two years not knowing it was a 6 cylinder distributor with a four cylinder cap stuck on it. That caused some weird problems ! Ends up it was from a Deere 4010, not a 1010. Had a six-lobe points cam. So, I found a very rusty four-lobe cam from a Case tractor and that fixed those particular weird problems. But the cam is very rusty and pitted and wears down points rubbing blocks pretty quick.
Note - a four cylinder engine runs pretty good with a six cylinder distributor but does some very strange things. One is severe carbon tracking and burning out caps very quickly.

So, since I've had it, it has never had the complete original ignition system -but I never figured it mattered. OEM it would of had a ballast resistor built into the key swith, a low-ohm 6 volt type coil, and a cranking- resistor-bypass built into the key switch to allow full voltage to the coil which cranking.

I installed a standard battery key switch, 6 volt low-ohm coil, external ballast resistor, and a cranking- bypass wirred to the Delco starter. I assume Deere did NOT do this since some 1010s had Prestolite starters and they do not have the bypass feature.

I used the crawler this way for many years. Then recently I started getting a problem that once good and hot after running for hours, the engine would just quit. If I let it sit for a few minutes it would start right up and sometimes run fine for hours. Or - sometimes just quit aqain. Seems to be some sort of intermittent ignition problem. I was always able to restart so I never spent much time trying to diagnose.

This spring I had a big pond project and I knew I'd be using the 1010 a lot. In fact, I literally ran the tracks off it. Before the project, I decided to install a Pertonix breakerless kit. I do NOT believe all the wonderous BS stories about engines running better with Pertonix. I did it to elimate points wear only. The reason was that the four-lobed cam in the distributor was in bad shape and was hard on points. By using the breakerless module, I eliminated the rusted-pitted cam. But - the Pertonix "Ignitor" kit does not allow use of a low-ohm 6 volt type coil unless a resistor is wired in. It will void warranty. So for simplicity, I bought a brand new high-ohm "12 volt" coil. 3.2 ohms instead of 1.5 ohms on the primary. Afterwards I ran the crawler almost all day, every day for two weeks and it ran flawlessly. But this was an unusual warm spell and it never got colder then 60 degrees F. Now the weather has cooled down -into the 30s and 40s F. The crawler is near impossible to start. I tried widening the plug gap from .025' to .035" and it made no difference. If anything, it might be worse. I tried altering the timing and no changes made any difference. Sometimes I have to fool with it for half an hour and finally it will start. When it does it runs perfect. Note - the choke on the carb works fine. In fact it's pretty easy to flood. This problem seems to be a "yes" or "no" sort of thing. No inbetween. I tried checking spark during the time when it was not starting. With a plug wire hooked to a plug (with ground electrode broken off), and cranking it - it threw a good spark jumping near 1/4". So I'm stumped when it comes for further diagnosis. I DO know that it takes more energy to make a spark inside a combustion chamber so my open-air test is not perfect. I think now I'm going to start changing parts.

One piece of evidence though. One time after cranking for half an hour - I removed one spark plug. I then cranked and it started right up - even though it only had 3 cylinders. So what did removing one plug do? I assume cranking speed increased since the compression of one cylinder was missing. I then put the plug back in and checked actual voltage to coil when cranking. Voltage goes down to 8 volts. So I'm now wondering if maybe this Pertonix breakerless module has a sort of "yes" or "no" threshhold when voltage drops below a certain point - or cranking speed drops below a certain RPM. To add to this maybe my starter is drawing more current then it ought to resulting in the voltage drop to 8 volts when cranking? Seems it ought to only drop to 9 or 9.5 volts, not 8 volts. It is NOT a cable or connection problem Even drops to 8 when checked at the battery.

I do know this. This 1010 starts much better with the former 6 volt coil with ballast resistor and breaker-points. Obviously with the 6 volt type coil - as the 1010 came new - and the cranking bypass - 8 volts at cranking is plenty.

Right now I suspect the Pertronix as the issue. When I bought it I was planning to use a low ohm 6 volt type coil. After opening the box I was surprised to find out it can’t be used with any coil less then 3.2 ohms or it will burn out. This is the standard Ignitor system - version # I. Version II and version III allow better coils but Pertonix does not make those versions for many older tractors.


Replies:




Add a Reply

:
:
:

:

:

:

:

:

:

Advanced Posting Options

: If you check this box, email will be sent to you whenever someone replies to this message. Your email address must be entered above to receive notification. This notification will be cancelled automatically after 2 weeks.



 
Advanced Posting Tools
  Upload Photo  Select Gallery Photo  Attach Serial # List 
Return to Post 

TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Today's Featured Article - History of the Nuffield Tractor - by Anthony West. The Nuffield tractor story started in early 1945. The British government still reeling from the effects of the war on the economy, approached the Nuffield organization to see if they would design and build an "ALL NEW" British built wheeled tractor, suitable for both British and world farming. ... [Read Article]

Latest Ad: Oliver 550 Diesel runs like a watch three point hitch pto engine gone threw about two hundred hours ago nice clean tractor [More Ads]

Copyright © 1997-2024 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.