Tractor Talk Discussion Board |
Re: TO-35 Coil Problems
[ Expand ] [ View Replies ] [ Add a Reply ] [ Return to Forum ]
Posted by John T on April 01, 2006 at 12:39:19 from (66.244.90.98):
In Reply to: TO-35 Coil Problems posted by Brian Harrell on April 01, 2006 at 12:02:43:
Brian, with the Ignition ON and IFFFFFFF the points and points and points wiring are good and assuming the distributor is getting a good ground, when the points are closed (as they usually are) you should read voltage on the coils high input (from switch NOT to distributor) terminal BUT THERE SHOULD BE NEAR ZERO VOLTS on its to distributor terminal, as the points should have that dead grounded. THEREFORE If youre reading voltage on BOTH sides of the coil, the points arent closing or are bad or the distributor isnt getting a good ground. If you place a test lamp on the coils to distributor terminal and crank the engine over the lamp should flash on (points open) and off (points closed). Check the points to see if they are set right and fully closing and then check the wires from the coil to the distributor and from inside the distributor over to the points and make sure the pass through terminal is good and has continuity. The points MUST close which takes the coils low side to a good ground so it can conduct current and then when the points break open the coil will fire. John T
Replies:
Home
| Forums
| Order Support
Today's Featured Article -
The Revival of a John Deere Combine - by The Red, John Fritz. For several years I had been driving by a farm house on the west side of Indianapolis that had a John Deere combine parked in high weeds in a lot behind the house. The gentleman no longer farmed because the entire area was developed with housing and light industry. I had stopped several times and knocked on the door but no one would answer. My curiosity was up and I wanted to contact the owner. I wanted to see what he planned to do with the combine.
... [Read Article]
Latest Ad:
For sale Farmall super A tractor is complete and has just been setting for awhile,it was running when pulled out of the barn,shouldn’t take to much to get it going asking 1100.00
[More Ads]
Copyright © 1997-2026 Yesterday's Tractor Co. All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V. Yesterday's Tractors - Antique Tractor HeadquartersWebsite Accessibility Policy |
|