Tool Talk Discussion Forum

Water Heater Tank...PSI Rating

Welcome Guest, Log in or Register
Author 
Glenn FitzGeral

04-04-2008 09:43:01




Report to Moderator

What is the maximum PSI rating of current water heater tanks?

Thanks,
Glenn F.




[Log in to Reply]   [No Email]
jeffcat

04-06-2008 18:11:31




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to Glenn FitzGerald, 04-04-2008 09:43:01  
Now everyone is going to scream! Several months ago the show Myth Busters took electric water heaters and took out the saftey "Temp/pressure" valve. Next they bypassed the high limits. Fill it with water and plug it in. When it blew it went up over 500 feet! I can't remember if it was 200 or 300 pounds. This is stuff you do not need to know!



[Log in to Reply]  [No Email]
Why?

04-05-2008 11:26:14




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to Glenn FitzGerald, 04-04-2008 09:43:01  
Since no one asked, why do you need to know? It looks like everyone is thinking you want to use a new water heater tank for a compressed air tank. Maybe you just want to know how much the water pressure rating is for setting up a pump from a well or cistern? Most water systems have a pressure around 55 or 60 PSI but some are as high as 100 PSI. The tank should say on it the safe working "water" pressure. Large oilfield holding tanks are tested with only 1 1/2 to 2 PSI air pressure. When the air is let out of a 3/4 or 1 inch valve, you'd swear there was 300 PSI in there. It almost blows you over when you walk by. Water under pressure is safer than air under pressure and that's why higher pressure vessels are hydrostatic tested. Filled with water under pressure. You know what they say about assuming things.

[Log in to Reply]  [No Email]
MarkB_MI

04-06-2008 04:31:09




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to Why?, 04-05-2008 11:26:14  
I think everyone assumed that Glenn is the same Glenn F. that posted earlier about adding a tank to his air compressor.

I'll chime in with all the earlier posts that using a hot water tank to hold air is not a great idea; the walls are very thin even when new. And if anyone is concerned about the water pressure in their house, a regulator is cheap insurance.



[Log in to Reply]  [No Email]
buickanddeere

04-05-2008 09:45:31




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to Glenn FitzGerald, 04-04-2008 09:43:01  
I would never consider using a hot water tank. They are ancient energy wasting technology that run cold too soon.
Install a tankless instant heater and you will wonder why you didn't sooner.



[Log in to Reply]  [No Email]
old art

04-04-2008 19:58:18




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to Glenn FitzGerald, 04-04-2008 09:43:01  
some villages here in northern il. have city water pressure of 100 lbs. because of rolling ground levels it is hard on water mains when you get a hydrolic hammer by pumps comming on line at a 1000 GPM. water heaters got to have a good pressure relase valve.



[Log in to Reply]  [No Email]
Charles (in GA)

04-05-2008 07:40:52




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to old art, 04-04-2008 19:58:18  
Thats why most public water systems require each customer to have both a regulator limiting to about 60 psi and a back flow check valve, on the supply line, at the meter.

I spent some time looking at water system web sites trying to see if there was some commonly accepted minimum pressure, and found water systems that warned that in certain areas, the pressure in the mains would be close to 200 psi at times, due to terrain, elevation of tanks, etc.

Charles

[Log in to Reply]  [No Email]
school boy

04-04-2008 10:20:52




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to Glenn FitzGerald, 04-04-2008 09:43:01  
I have used on for air for years. It is set to cut off at 100psi. Psi is Psi regardless of water or air. They are both considered fluids. I saw myth busters put an ungodly amount of pressure in one to make it blow up. Even then usually just released out a small opening without an explsion.



[Log in to Reply]  [No Email]
David - OR

04-05-2008 06:36:32




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to school boy, 04-04-2008 10:20:52  
NO, air and water are NOT both considered fluids. Frankly, such a statement seems contrary to what we learned in elementary school. Three states of matter; solids, liquids, gases, remember?

Air is a mixture of gases and can be compressed. Compressed gases store energy. That is the point of the tank, after all. If a tank full of compressed air ruptures, it releases that energy, potentially all at once (explosively). Just like a balloon popping. (In the Myth Buster clip another poster kindly provided, the bottom tore off the water heater, the heater blew a hole through the roof, and launched itself 100's of feet in the air. This at 325 PSI.) Not "an ungodly amount" at all -- only 2x the pressure rating is not much of a safety factor, especially after the tank gets weakened by rust).

Liquids cannot be (significantly) compressed. 100 PSI water does not store energy. Overpressure a tank with liquid and there's no drama when it finally breaks. That's why compressed gas tanks are hydrostatic tested, for example. That's why PVC pipe is safe for 450 PSI water, but not 450 PSI compressed air.

The FLOW of air and water can be modeled by considering both to be "fluids". This only works for relatively low velocities. But the reaction of both to pressure is very different.

[Log in to Reply]  [No Email]
Gumby

04-05-2008 09:09:04




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to David - OR, 04-05-2008 06:36:32  
Gases and liquids are indeed both fluids, because by definition they both "flow". Just because they have different properties under various conditions doesn't exclude them from this definition, anymore than steel and concrete both shouldn't be considered solids, because under various conditions, they have different properties.



[Log in to Reply]  [No Email]
David - OR

04-05-2008 10:10:42




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to Gumby, 04-05-2008 09:09:04  
Fine. Air and water both flow and can be considered fluids from that perspective. But "flow" is not the relevant issue in this discussion. The issue here is safety of a pressure vessel. 50 gallons of air at 100 PSI has the stored energy of a stick of dynamite. 50 gallons of liquid water at 100 PSI has the stored energy of a speck of sawdust (or less). Air and water ARE NOT BOTH FLUIDS when it comes to COMPRESSIBILITY.

The similarity of water and air from one perspective should not be used to rationalize an unsafe mis-use of a water heater for compressed air storage.

[Log in to Reply]  [No Email]
T_Bone

04-05-2008 10:47:40




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to David - OR, 04-05-2008 10:10:42  
I agree with School Boy and Grumby as air being a fluid. It would be difficuclt to calculate engineering designs if air was not a fluid.

From Websters online:

"1 a: having particles that easily move and change their relative position without a separation of the mass and that easily yield to pressure : capable of flowing b: subject to change or movement
2: characterized by or employing a smooth easy style
3 a: available for various uses b: liquid 4 "

However, I totally agree with David's explanation of why a hot water tanks should NOT be used as a air tank as I've learned never to say never. Never happens, shows up all the time and just when you least expect it too.

T_Bone

[Log in to Reply]  [No Email]
George G

04-04-2008 18:48:51




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to school boy, 04-04-2008 10:20:52  
I would rather have a tank split open with 100psi water, than to have it explode with a 100psi air.



[Log in to Reply]  [No Email]
Gary from Muleshoe

04-04-2008 17:26:43




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to school boy, 04-04-2008 10:20:52  
I saw that myth buster show also. I was amazed at how much pressure one would hold. If I remember right they even plugged the pop off and still did not blow the tank up.



[Log in to Reply]  [No Email]
mythbuster?

04-05-2008 05:57:43




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to Gary from Muleshoe, 04-04-2008 17:26:43  
Relook at that mythbuster show again that tank did blow up Steam very dangerous....



[Log in to Reply]  [No Email]
Bob

04-05-2008 08:35:48




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to mythbuster?, 04-05-2008 05:57:43  
The REAL danger is the "superheated" WATER in the tank. Once the pressure is released when the tank ruptures, it INSTANTLY "flashes" to steam. THAT is what propelled the tanks upwards in the MythBusters "experiments".



[Log in to Reply]  [No Email]
fixerupper

04-05-2008 08:00:24




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to mythbuster?, 04-05-2008 05:57:43  
That Mythbuster segment was awsome. I'd sure hate to have that sucker go off in my basement. Jim



[Log in to Reply]  [No Email]
old

04-04-2008 10:11:49




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to Glenn FitzGerald, 04-04-2008 09:43:01  
The built in pop offs pop at around 150PSI, but when they are made they are pressure test up to 300psi. I use one for a pressure tank on my truck air system and it has worked just fine for years. I do not stand close to it when I use it and the pop off has popped a few times over the years and when it does it scares the #$#%

[Log in to Reply]  [No Email]
Bob

04-04-2008 10:06:33




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to Glenn FitzGerald, 04-04-2008 09:43:01  
My fairly new 52-gallon electric heater is labeled:

"HYDROSATIC working pressure 150 PSI"

I'll ASSUME that's an ENTIRELY different situation than what such a thin tank would be rated for air pressure!

If you are thinking what I suspect you are thinking DON'T DO IT!



[Log in to Reply]  [No Email]
Floyd A tn

04-04-2008 09:55:53




Report to Moderator
 Re: Water Heater Tank...PSI Rating in reply to Glenn FitzGerald, 04-04-2008 09:43:01  
60 lbs is usually the highest. You could probably go more but i wouldn't suggest it.



[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy