Welder extension cord

Welcome Guest, Log in or Register
Author 
BobPa.

02-13-2008 09:57:22




Report to Moderator

Hi. I have a Lincoln 175 mig welder. The manual says to use 8 ga. wire and a 40 amp breaker. I have 60 ft. of 8 ga wire to make an extension cord, but my wire is 3 wire (black,white,green)and my welder is 220V. Is it OK to use the black and white as hot, and the green as neutral? I"m guessing this would be OK because my plug only has three prongs. But I wanted to ask to be sure. Thank you.




[Log in to Reply]   [No Email]
Joe(TX)

02-15-2008 05:41:43




Report to Moderator
 Re: Welder extension cord in reply to BobPa., 02-13-2008 09:57:22  
If the plug has 3 prongs, it has no neutral. It has a ground. The black and white are the line. The green GROUND. The 8ga is ok if as long as you are not going over 100 ft.



[Log in to Reply]  [No Email]
Bob Huntress

02-13-2008 20:49:47




Report to Moderator
 Re: Welder extension cord in reply to BobPa., 02-13-2008 09:57:22  
BobPa, when the manual calls for a minimum of 8ga wire, I doubt they intended that a 60' cord would be 8 ga. Depending on the load you will be placing on your welder, you may want to check and verify that at 60' of extension cord you will not be required to use a heavier wire.



[Log in to Reply]  [No Email]
Bus Driver

02-14-2008 16:40:33




Report to Moderator
 Re: Welder extension cord in reply to Bob Huntress, 02-13-2008 20:49:47  
Depending on the duty cycle of the welder, the amperage draw/protection of supply conductors for welders can be higher than for most other applications. Article 630 NEC. My bet is that the #8 at 60 feet will be fine.



[Log in to Reply]  [No Email]
36 coupe

02-15-2008 02:20:48




Report to Moderator
 Re: Welder extension cord in reply to Bus Driver, 02-14-2008 16:40:33  
I been using a welder on 150 feet of #8 for 40 years.The welder is not used at max current often.We are getting 244 volts here on the end of a three phase line.Have someone monitor the line voltage while you are welding.



[Log in to Reply]  [No Email]
BobPa.

02-13-2008 15:59:56




Report to Moderator
 Re: Welder extension cord in reply to BobPa., 02-13-2008 09:57:22  
Thanks everybody. Yes, the welder is 240 volt, not a 120volt machine. It takes a double pole breaker rated at 40 amps. The unit does have a fan in it. Only other thing I wired 240 volt was a couple of clothes dryers and they had a seperate appliance ground (4 wire).



[Log in to Reply]  [No Email]
John T

02-14-2008 08:23:24




Report to Moderator
 Re: Welder extension cord in reply to BobPa., 02-13-2008 15:59:56  
Bob, The fan is likely a 240 volt motor so again, 240 is alllll lllll you need i.e. NO NEUTRAL NO 12O VOLTS..... . 2 Hots, 1 Equipment Ground.

On modern appliances (maybe a range or dryer) that require 4 wire versus the old 3 wire units, that could be from it using BOTH 120 (maybe controls or an outlet) anddddd 240 volts (motor and heating units). Therefore its 2 (Red n Black) hots,,,,,1 Neutral (White grounded conductor),,,,, 1 Bare/Green Equipment Grounding Conductor

John T

[Log in to Reply]  [No Email]
Gerald J.

02-13-2008 18:56:46




Report to Moderator
 Re: Welder extension cord in reply to BobPa., 02-13-2008 15:59:56  
If the fan runs on 120 volts and if you don't mind being connected to 120 volts through the fan when the ground/neutral breaks you can wire it with three wires. The code calls for four wires so breaking the neutral doesn't put 120 volts on the case. You might survive 120 volts through the fan and you might not. Getting the heart out of fibrilation takes a defibrilator otherwise you die.

Its as simple as that.

Gerald J.

[Log in to Reply]  [No Email]
Bus Driver

02-13-2008 16:27:34




Report to Moderator
 Re: Welder extension cord in reply to BobPa., 02-13-2008 15:59:56  
My Lincoln welder has a 240 volt fan. I suspect that is the case very often.



[Log in to Reply]  [No Email]
BobPa.

02-13-2008 16:56:40




Report to Moderator
 Re: Welder extension cord in reply to Bus Driver, 02-13-2008 16:27:34  
Thanks Bus Driver. I always get good help from everybody on this forum. You are all a bunch of good people. I read this site a lot and always learn something new.



[Log in to Reply]  [No Email]
IH2444

02-13-2008 15:04:53




Report to Moderator
 Re: Welder extension cord in reply to BobPa., 02-13-2008 09:57:22  
Just a comment or 2 here. I have a welder with 3 prong 220v connector it does use 120V for the fan inside.
My electric range is the same way for the clock in it.
I wire the third prong to neutral. In these types of cases. Yes 4 wire is the code now, but if your home/shop is not wired for the 4 wire 220v outlets....



[Log in to Reply]  [No Email]
Bus Driver

02-13-2008 14:38:22




Report to Moderator
 Re: Welder extension cord in reply to BobPa., 02-13-2008 09:57:22  
if the cable you have is Type NM or SE, it is not suitable for use as an extension cord.



[Log in to Reply]  [No Email]
NE IA

02-13-2008 14:08:22




Report to Moderator
 Re: Welder extension cord in reply to BobPa., 02-13-2008 09:57:22  
I do some electrical work, mostly buildings / houses. Take this with a grain of salt, but I kind of think you must have a four wire if it is 240 acording to a electrician in my home town. I realize that sometimes it is simpler to ignore the actual code in certian cases.

We have a heavy cord for temporary service 250 ft long that will handle 100 amps plus. I can tell you this, nothing helps maintain a cord any better than a good head on your shoulders and a constant eye for abuse. Rubber cords do not stretch, they are not intended to pull foreign objects when they get tangled on them. They are not designed to support tractor, skid loader, or buldozer traffic. Knots do not undo themselves, get over the thought that they will after if ignored.

[Log in to Reply]  [No Email]
Stan in Oly, WA

02-13-2008 16:49:27




Report to Moderator
 Re: Welder extension cord in reply to NE IA, 02-13-2008 14:08:22  
In the welding shop at the local community college, the students so consistently step on the extension cords and pneumatic hoses that I once asked the department head if they had been told that they were supposed to do that. (They hadn't been).

I used to think that young people would feel differently about the equipment they abused if they had to spend their own money on it. I no longer believe that's the case. I think people who are inclined to take care of equipment will take care of it regardless of who it belongs to, and those who abuse equipment without giving it a thought will abuse their own equipment the same way. I suspect that part of it comes from being raised in a commercially oriented culture where everything is disposable. If they even thought about it they would probably think something like, "Why not grind the extension cords into the concrete instead of stepping over them? We'll have to buy new ones sometime anyway." But I don't think they actually ever give it a thought.

I thought that rant would make me feel better, but it didn't.

All the best, Stan

[Log in to Reply]  [No Email]
John T

02-13-2008 14:54:28




Report to Moderator
 Re: Welder extension cord in reply to NE IA, 02-13-2008 14:08:22  
If the appliance has BOTH 120 AND 240 and requires an equipment ground THEN YES IT REQUIRES 4 WIRES AS YOU SUSPECTED (2 Hots, 1 Neutral (a grounded conductor), 1 Equipment Ground)

HOWEVER if THE APPLIANCE (LIKE SAY A 240 VOLT ONLY WELDER) is straight 240 volt with NO 120, a Neutral IS NOT REQUIRED... In that case 3 wires will suffice and be in full compliance with the NEC, 2 Hots and 1 Equipment Grounding Conductor..... .

Hope this helps, yall take care n be safe now

John T

[Log in to Reply]  [No Email]
Stan in Oly, WA

02-13-2008 12:38:42




Report to Moderator
 Re: Welder extension cord in reply to BobPa., 02-13-2008 09:57:22  
Hi Bob,

I made a couple of extension cords like you're talking about, and the weakest part seems to be the attachment of the cable to the plug. The outlet end isn't so bad because you can put the outlet in a steel electrical box and use a steel clamp (wire loom, I think it's called) to hold the cable in place. The plugs I've seen, however, have built in clamps which are not sturdy enough to hold the cable as firmly as it should be held. Those plugs would be adequate where you plugged in the cord once and then left it there, as you would with a range or dryer. Mine have tended to work themselves loose when I use my extension cords as extension cords. Let me know if you work out a way to deal with this problem.

All the best, Stan

[Log in to Reply]  [No Email]
CWL

02-13-2008 13:10:58




Report to Moderator
 Re: Welder extension cord in reply to Stan in Oly, WA, 02-13-2008 12:38:42  
There is a better quality plug available for this application. It is a fairly high dollar item though. Last time I looked at one it was over $50, but it has a better strain relief clamp than the cheaper plugs. Most electrical wholesale places can fix you up with one.



[Log in to Reply]  [No Email]
IH2444

02-13-2008 12:47:51




Report to Moderator
 Re: Welder extension cord in reply to Stan in Oly, WA, 02-13-2008 12:38:42  
On the lose plugs I use silicone goopy glue/caulk liberally around the cord when I clamp it in. Not perfect but better than without it.
I also usually put a few layers of heat shrink up the cord a few inches from the plug as a sort of strain distrubution thingy.



[Log in to Reply]  [No Email]
soundguy

02-13-2008 11:54:39




Report to Moderator
 Re: Welder extension cord in reply to BobPa., 02-13-2008 09:57:22  
As johnT said... if it is 3 prong.. it will be hot/hot/grnd.. not neutral.

Soundguy



[Log in to Reply]  [No Email]
buickanddeere

02-13-2008 10:50:28




Report to Moderator
 Re: Welder extension cord in reply to BobPa., 02-13-2008 09:57:22  
North America or Europe?



[Log in to Reply]  [No Email]
John T

02-13-2008 10:21:54




Report to Moderator
 Re: Welder extension cord in reply to BobPa., 02-13-2008 09:57:22  
Bob, its my best guess sittin here without the welder in front of me that its straight 240 volt i.e NO NEUTRAL NO 120 VAC USED..... . If so and it has a 3 prong plug they would be two hots (240 VAC) and an Equipment Grounding Conductor usually Green or bare which is bonded to the welders metallic case/frame. That being said and assuming??? its correct, the wire you have could consist of a black n white hot and then green would be for the Equipment Ground (NOT Neutral as you stated) although the normal would be red n black as hots n green/bare for the EGC.....

If the welder were only 120 volt then it would have a single black hot, a white Neutral, and a green EGC.

BUTTTTT TT if it wires to a TWO POLE CIRCUIT BREAKER INSTEAD OF A SINGLE POLE,,,,, ,, That tells me its 240 volts and my best guess above is likely correct..... ...

John T long retired electrical engineer so a lil rusty

[Log in to Reply]  [No Email]
mjbrown

02-13-2008 10:02:11




Report to Moderator
 Re: Welder extension cord in reply to BobPa., 02-13-2008 09:57:22  
That is the way mine is.



[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy