Tool Talk Discussion Forum

Generator question

Welcome Guest, Log in or Register
Author 
Jimdril

12-11-2007 18:51:36




Report to Moderator

Just went 10 hours with no power and decided to take the plunge and get a gen. As I live on a farm and my power comes thru a yard pole with a shutoff, I plan to backfeed the gen thru a welder outlet in my shop. I can pull the fuses at the pole before I hookup. Any problems with this setup?




[Log in to Reply]   [No Email]
AL 2

12-12-2007 21:05:13




Report to Moderator
 Re: Generator question in reply to Jimdril, 12-11-2007 18:51:36  
I just had a switch attached to my meter that the generator plugs into. The same type of thing that Ron was talking about. Made by GenerLink and is installed by an electrician in about ten min. after he removed the meter. Did not need to come into the house and I can use any breakers that I need. Just turn off the ones that may overload your service as required. I bought mine outright ( $1000.00 in my area of Canada) but see that some utilities may rent them.
Look here:>Link
Al>Link

[Log in to Reply]  [No Email]
ScottyHOMEy

12-12-2007 19:17:55




Report to Moderator
 Re: Generator question in reply to Jimdril, 12-11-2007 18:51:36  
Don't do it!

They make a simple, foolproof transfer switch that makes it physically impossible to backfeed the line, but it requires breakers, not fuses in the box. It has to be ordered to fit your box, and it basically introduces a sliding plate with a hole that your toggles on your mains pass through. you move the breakers from the top two slots on one side of your box to a different location, and replace them with a double ganged breaker that switches the feed from an outlet you have installed strictly for your gen set. That sliding plate prevents the feed breaker from feeding the box until the mains are off, and the mains can not be reconnected to the line until the breakers are thron back off, disconnecting the generator from your box.

Unfortunately, not much use with a fuse box, and the cost can vary, depending how much entrance cable you need to run from the outside plug to the box. Mine is a short run, and it cost me $600 to put in. But it's well worth the peace of mind knowin' I'm not gonna blow up the gen set or burn the place down. Most important is that I'm not puttin' the guys who are bustin' their humps in nasty weather tryin' to get the lines fixed in danger of their lives.

[Log in to Reply]  [No Email]
buickanddeere

12-12-2007 16:31:57




Report to Moderator
 Re: Generator question in reply to Jimdril, 12-11-2007 18:51:36  
On page 2 after this there is another generator question with more answers. Is the backfeed idea ok? Just go down to the local electrical utilty worker's coffee shop and tell then you are back feeding your house through a welding receptacle and no transfer switch. P.S. post your mailing address before telling the utility workers so we can send sympathy cards to your family.



[Log in to Reply]  [No Email]
GlennF.

12-12-2007 10:08:38




Report to Moderator
 Re: Generator question in reply to Jimdril, 12-11-2007 18:51:36  
I have often thought about that too. Basically, the entire crankcase is a mixing chamber for the gas/oil and air. The flow of the mixture caused by the piston bringing in a new mix each cycle keeps things lubricated; even the bearings. Pretty amazing.

Glenn



[Log in to Reply]  [No Email]
Glenn F.

12-12-2007 10:11:26




Report to Moderator
 Re: Generator question in reply to GlennF., 12-12-2007 10:08:38  
Oops! This comment belongs in the two-cycle thread down the page.

Glenn



[Log in to Reply]  [No Email]
JMS/.MN

12-12-2007 09:22:24




Report to Moderator
 Re: Generator question in reply to Jimdril, 12-11-2007 18:51:36  
Only problem is the ability to kill people! If you were in our REA, you would be disconnected with such a setup. You need a double throw disconnect mounted at the pole, by a licensed electrician, along with the proper box/cables mounted at the bottom, to connect to your generator. You"re going to "plug" in to the welder outlet? If the generator is running while you do that, those prongs are hot, and some day you might forget to shut off the genny before unplugging the cable. Then you"re dead. Otherwise, it"s just the linemen that you kill, by forgetting to pull the pole fuses first.

[Log in to Reply]  [No Email]
evielboweviel

12-12-2007 08:22:49




Report to Moderator
 Re: Generator question in reply to Jimdril, 12-11-2007 18:51:36  
South Central Power supplies my house. They have offered to install a device in the meter that will allow me to plug a generator into it. Rated 6kw I believe. This puts all the liablity on them and none on me.
Cost quoted was 600 installed. I have not done this due to all underground wiring around me and rarely without power. Would have had it done at my last house due to all the outages there
Ron

[Log in to Reply]  [No Email]
El Toro

12-12-2007 08:22:15




Report to Moderator
 Re: Generator question in reply to Jimdril, 12-11-2007 18:51:36  
You only need to furnish power to a few items. I disconnect the items I want to power from the house power. A few items are your freezer, refrigerator, well pump if you're on well water, furnace and few lights. My water heater has electronic ignition instead of a pilot light and I powered it when the power was off. In less than 5 minutes the water was hot. Hal



[Log in to Reply]  [No Email]
old

12-12-2007 07:30:42




Report to Moderator
 Re: Generator question in reply to Jimdril, 12-11-2007 18:51:36  
As John says do it right. In my case I say do it right or not at all it could save your life or others life. Next you would need a pretty big genny to do as you want also since doing that would feed every thing you have and that takes a lot of watts to do that. A little say 6.5KW genny will not even begin to do what you want and the ones you need to run every thing are going to cost you $2000-10,000 depending on what you get. So you also have to figure if its worth it in the long run. Most of the time a genny like that gets used at best once every year if even that much

[Log in to Reply]  [No Email]
John T

12-12-2007 07:44:42




Report to Moderator
 Re: Generator question in reply to old, 12-12-2007 07:30:42  
Rich, Another important thing for guys that have gennys which may be overlooked IS TO USE N EXERCISE THEM on a regular basis, otherwise when you really need them the carbs will be full of gum n varnish n the fuel stale grrrrr rrrrr r. When we used to spec large gennys where I worked we required automatic exercise schedules as part of the automatic control and transfer package and at certain intervals the fuel tanks got drianed n refilled n flushed etc. I dont keep one now cuz the genny in my RV could serve the purpose.

Any ice down your way????? ??

JT

[Log in to Reply]  [No Email]
JT

12-12-2007 19:33:59




Report to Moderator
 Re: Generator question in reply to John T, 12-12-2007 07:44:42  
An other reason to use a genny at least once a month is not to loose the charge in your capacitor if you have a low dollar generator. We get a lot of the cheap gennies in to work on that have sat for a while and they do not work. customer said it worked when he used it a year ago. On better quality gennies, we have to flash them to get to charge after they sit with no use. on the cheaper ones, like Coleman/Powermate and most all the chinese gennies, you have to replace the capacitor. I have tried to recharge the capacitors, it normally does not work, so it needs replaced.

[Log in to Reply]  [No Email]
old

12-12-2007 07:50:32




Report to Moderator
 Re: Generator question in reply to John T, 12-12-2007 07:44:42  
Had some ice but not enough to casue me any problems this time. Its still raining and has been now for days, last 4 or 5. Got a call this morning and the guy with the JD-D said he would take my offer for it so now I get the fun of hauling it home and with all the mud we have that could end up being fun.
And yes a genny needs to be used 2 or 3 time a year or set up so it has no gas etc when not being used whcih is what I do with mine. I drain the carb and since it doesn't have its own tank the tank isn't a problem

[Log in to Reply]  [No Email]
El Toro

12-12-2007 05:29:30




Report to Moderator
 Re: Generator question in reply to Jimdril, 12-11-2007 18:51:36  
I think you should call a licensed electrician and have it done according to your local codes. It's better to be safe than sorry. Hal



[Log in to Reply]  [No Email]
JerryU

12-12-2007 03:58:36




Report to Moderator
 Re: Generator question in reply to Jimdril, 12-11-2007 18:51:36  
I am sure you will have some linemen weigh in on this, but in some utility service areas, if they catch you back feeding you can be disconnected.

At minimum, I would recommend a manual transfer switch.

JU



[Log in to Reply]  [No Email]
Jon Hagen

12-12-2007 11:45:33




Report to Moderator
 Re: Generator question in reply to JerryU, 12-12-2007 03:58:36  
My uncle did that, was without power for over a week during a teriffic ice storm with cattle to water and a hot water heating system that needed power to work. He bought a gen set and connected it to a welder socket in his shop and turned off his main breaker. He got away with this dangerous lash up until the day the power was restored. He turned the main breaker on with his shut down genset still plugged into the welder socket in the shop. The generator windings actually exploded, bits of hot copper wire flew out of the generator vent slots and melted a hole in the engines rubber fuel line,draining several gallons of gasoline on the shop floor. Only dumb luck prevented burning the shop down. The fireworks must have been over before any gas leaked out through the melted line. Cost to rebuild the generator exceeded half the original price of this heavy expensive contractor type genset.

[Log in to Reply]  [No Email]
TyTX

12-11-2007 21:29:16




Report to Moderator
 Re: Generator question in reply to Jimdril, 12-11-2007 18:51:36  
John has a good point but I've had better luck explaining it with this take.....

If your generator is connected to the power grid (like if you forgot to pull those fuses) when the power comes back on... there will be a smoking hole where your generator used to be and it could catch the house/barn on fire.

That word picture seems to create a lot of understanding.



[Log in to Reply]  [No Email]
bill mart

12-12-2007 01:54:23




Report to Moderator
 Re: Generator question in reply to TyTX, 12-11-2007 21:29:16  
if the generator was trying to feed the whole power grid because he forgot to pull the fuses wouldnt it stall out or pop its circuit breakers because the load was too large?Besides isnt he using a cut-off not a circuit breaker panel?



[Log in to Reply]  [No Email]
John T

12-12-2007 07:10:29




Report to Moderator
 Re: Generator question in reply to bill mart, 12-12-2007 01:54:23  
Bill your point is well taken and legitimate buttttt ttttt the first load his genny would see is the pole or pad mount local residential transformer secondary winding and the load depends on what all is currently connected over on the other HV side, its NOT like the entire grid is there instantaneously. The problem is as soon as the genny comes on line ther would be for some time at least (regardless if for a short time) something like 9600 volts (depends on the utilitys distribution voltage) over on the primary and it only takes something like 50 milliamps for not very long through the linemans ticker n he diesssss sssss

Would you wanna take the chance or volunteer to hold on to the transformer n see if you live until his genny craps out????? ???

Of course, he intends to turn off the main shut off to prevent this buttttt ttttt people have died when good intentions didnt get practiced.

Again, Im NOT telling anybody what to do, just trying to point out the potential hazards n encouraging people to DO IT RIGHT

take care yall

John T

[Log in to Reply]  [No Email]
bill mart

12-12-2007 15:15:27




Report to Moderator
 Re: Generator question in reply to John T, 12-12-2007 07:10:29  
Just want to make it clear I agree with you John, anyone backfeeding with a generator is asking for trouble be it from energizing the grid and killing someone or using a double male ended extension cord and killing themselfs when they start the genset and touch the hot end of the cord.Bill M



[Log in to Reply]  [No Email]
John T

12-12-2007 18:44:33




Report to Moderator
 Re: Generator question in reply to bill mart, 12-12-2007 15:15:27  
Roger, we dont want to see anyone hurt n like you say either of those things is risky at best

John T



[Log in to Reply]  [No Email]
John T

12-11-2007 19:34:51




Report to Moderator
 Re: Generator question in reply to Jimdril, 12-11-2007 18:51:36  
As an electrical engineer I just have to suggest you get a proper Transfer Switch and do it in accordance with the NEC and your local authority. I guess you realize if the main breaker in your panbelboard (or the shut off you mentioned) isnt opened the 120 volts you apply via that genny can create several thousands of volts out on the utlty primary!!!!! !!!!!

A transfer switch makes your loads have to be switched from either the utility or the genny BUT DOESNT ALLOW YOUR GENNY TO BACKFEED THE UTILITY

Of course, if you have a utility shut off like you mentioned IF ITS OFF your genny cant backfeed the utlity, but I still have to advise a transfer switch

There are also rules concerning the grounding of a portable genny which need to be complied with to reduce hazards.

You may want to consult a local licensed n qualfied elecrician, sure its your house and Im NOT trying to tell you what to do buttttt tt Im sure you dont want to see anyone harmed either.

Best Wishes, keep safe

John T

[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy