Square D--QO vs. Homeline?

Welcome Guest, Log in or Register
Author 
Glenn FitzGeral

11-04-2007 05:14:26




Report to Moderator

I have 4 breaker boxes on my property; all of them being Square D QO (I think the letters are QO.) I've never figured breaker boxes were a place to save a couple bucks, but what are the differences between QO and Homeline? I know Homeline breakers are a little wider, don't have a red indicator showing when they're tripped, and snap in differently, but is there a difference in quality?

Thanks,
Glenn F.

[Log in to Reply]   [No Email]
dave guest

11-07-2007 20:24:09




Report to Moderator
 Re: Square D--QO vs. Homeline? in reply to Glenn FitzGerald, 11-04-2007 05:14:26  
Square D QO was the industry standard l5 years ago. Homeline was imported.



[Log in to Reply]  [No Email]
dave guest

11-07-2007 20:23:53




Report to Moderator
 Re: Square D--QO vs. Homeline? in reply to Glenn FitzGerald, 11-04-2007 05:14:26  
Square D QO was the industry standard l5 years ago. Homeline was imported.



[Log in to Reply]  [No Email]
Gene Davis (Ga.)

11-05-2007 19:47:21




Report to Moderator
 Re: Square D--QO vs. Homeline? in reply to Glenn FitzGerald, 11-04-2007 05:14:26  
If you want a nightmare just get a Federal Pacfic box and breakers!



[Log in to Reply]  [No Email]
Bill in IL

11-05-2007 17:50:30




Report to Moderator
 Re: Square D--QO vs. Homeline? in reply to Glenn FitzGerald, 11-04-2007 05:14:26  
I think like lee does too and try to keep one type of breaker around but I use the homeline version cause they are universal with GE, Seimons and Cutler Hammer BR type. It makes it easy to find a breaker anywhere even though the square D QO are probably about the most sensitive for overload protection. Using them around the farm in the winter I have noticed the QO to be the worst and the homeline to be the best. A little bit of cold weather and the QO's witch were inside the silo room would have to be taken out and heated up before I could get them working. One would think ice in the breaker but they were sheltered. The homeline's were out in the weather and they never missed a days work.

[Log in to Reply]  [No Email]
Gary in Geneva

11-05-2007 09:12:01




Report to Moderator
 Re: Square D--QO vs. Homeline? in reply to Glenn FitzGerald, 11-04-2007 05:14:26  
Homeline is the same physical breaker as Bryant, GE, Seamens, etc. QO is slightly better, but the gap is closing compared to 40 years ago.



[Log in to Reply]  [No Email]
Crem

11-05-2007 07:27:48




Report to Moderator
 Re: Square D--QO vs. Homeline? in reply to Glenn FitzGerald, 11-04-2007 05:14:26  
I believe that I read once where the Homeline has an aluminum buss where the breakers snap in and make contact and the QO has a copper buss.



[Log in to Reply]  [No Email]
Bus Driver

11-04-2007 10:37:17




Report to Moderator
 Re: Square D--QO vs. Homeline? in reply to Glenn FitzGerald, 11-04-2007 05:14:26  
I think the QO is the better of the two. While most home installations will never need many of the various types of breakers available, the QO has a tremendous variety. QO is often used in commercial and industrial installations. Nothing would prohibit the use of Homeline in such places, but most installers would not do so.



[Log in to Reply]  [No Email]
1936

11-04-2007 10:29:33




Report to Moderator
 Re: Square D--QO vs. Homeline? in reply to Glenn FitzGerald, 11-04-2007 05:14:26  
Square D pulled out of NC and went to Mexico. The empty building was pointed out to me. Have no idea if the quality changed?



[Log in to Reply]  [No Email]
RobMD

11-04-2007 09:31:01




Report to Moderator
 Re: Square D--QO vs. Homeline? in reply to Glenn FitzGerald, 11-04-2007 05:14:26  
It"s just a miserable mess in a home depot. I know one trip to get a QO 15 amp breaker resulted in me mistaking a homeline breaker for one. SO back to the store I went, and wishing that they never made the stupid homeline junk.

Keep things simple, square D!



[Log in to Reply]  [No Email]
jdemaris

11-04-2007 08:26:56




Report to Moderator
 Re: Square D--QO vs. Homeline? in reply to Glenn FitzGerald, 11-04-2007 05:14:26  
I've done several installations with Homeline boxes and breakers dating back around 10 years - so the Homeline stuff isn't all that new. I've never had a problem with any of it - but I can't say I've ever had a problem with any brand.
Years back, the standard in my area was Cutler Hammer CH series -that because the major local wholesaler carried that as the main brand and CH breakers were the cheapest. Not any more.

Square D QO has one advantage that probably means nothing to you. The QO breakers are DC rated as well as AC - whereas most other home-use equipment is AC only. So, QO get used a lot in solar-electric work where DC wiring is done.

[Log in to Reply]  [No Email]
DickelDawg

11-04-2007 07:07:55




Report to Moderator
 Re: Square D--QO vs. Homeline? in reply to Glenn FitzGerald, 11-04-2007 05:14:26  
Square D "QO" style panelboards, breakers, etc. have been around for MANY years. The newer style Square D "Homeline" products are an "economical" updated item. I've used Square D "QO" products for more years than I care to remember and have had no problems with them. A few years ago Square D was bought out by the Schneider group, a France based outfit. Since then I've tried to use other brands as much as I can.

[Log in to Reply]  [No Email]
Lee in Iowa

11-04-2007 06:25:36




Report to Moderator
 Re: Square D--QO vs. Homeline? in reply to Glenn FitzGerald, 11-04-2007 05:14:26  
Hi again, I don't know if there's any difference between the two or not, but I refuse to buy the homeline because I don't want to keep 2 different kinds of breakers around. When I needed one for the garage, and the store only had homeline indoor boxes, I bought an outdoor box. Lee



[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy