Hi All,
I have a question about which rods to use for vertical welding, both vertical up and vertical down t-fillet joints on 3mm to 6mm plate.
I remember a few years ago using E7018 (oerelikon supercito) and E7016 for vertical up on a dc machine, will these work ok on an ac machine or is there an ac version of these?

Also my local hardware shop have started stocking an air liquide E6013 RC rod called "overcord" what is the difference between this and the E6013 "fincord M" rod (as you can probably gather oerlikon/air liquide products are all they stock!)

[Log in to Reply]   [No Email]
LM

09-03-2007 01:30:23




Report to Moderator
 Re: Welding Rods Question in reply to LM, 09-02-2007 14:27:41  
Thanks for the response guys,
I'll get some more 7018 rods and try get the 7018 AC and see how i get on, I live in Ireland, oerlikon/air liquide with their ___cord rods are whats available locally and what the training centres here seem to use but murex/boc, hilco, esab rods are available at the eng. suppliers. I would usually use the "fincord m" E6013 for general work on the flat but remember once using another called "supercord" which old notes tell me was a 6013 too for vertical down dc with neat looking (but maybe not very strong)results , the "overcord" rods are an E6013 as well but i havent used them , why do these rods have different characteristics yet all are E6013's?, the reason I ask about ac is that i have an ac plant which I find nice to use ,I find the dc plant i have ok for tig welding but rather unpredictable for stick welding compared to other dc units i've used

[Log in to Reply]  [No Email]
LM

09-03-2007 01:40:07




Report to Moderator
 Re: Welding Rods Question in reply to LM, 09-03-2007 01:30:23  
Posted that reply before I was finished!
Sorry for all the ___cord references its just what i'm used to I've never used 6010 or 6011 rods, I'll try get a few and see how I go Thanks



[Log in to Reply]  [No Email]
135 Fan

09-03-2007 09:14:08




Report to Moderator
 Re: Welding Rods Question in reply to LM, 09-03-2007 01:40:07  
6010 and 6011 have a rougher looking bead but that is normal. You use a slight back and forth whipping motion with them most of the time. Dave



[Log in to Reply]  [No Email]
135 Fan

09-02-2007 20:05:20




Report to Moderator
 Re: Welding Rods Question in reply to LM, 09-02-2007 14:27:41  
Can you get Air liquide AC7018? Air liquide regular 7018 is the preferred rod up here. Every single pressure shop as well as testing and training facility uses it. Nothing else is very close which is probably why it costs a little more. Lincoln 5P+ 6010 is also the preferred 6010. Generally 7018 is recommended for uphand welding because it has superior penetration to downhand welding. That said, on thinner material for not too critical welds 7018 can be run downhand. Sometimes just so you don't burn through. There is no way a downhand 7018 is anywhere near the strength of a proper uphand weld. Downhand requires a much faster travel speed and leaves a concave weld. Uphand leaves a flat to just slightly convex weld profile that is superoir in strength. If you must go downhand on thin stuff weave the puddle side to side just enough so that the arc force can keep the slag out of the way. There's my tip of the day. 7016 is also a low hydrogen rod but is usually considered an earlier version before 7018 were made. In stainless steel however rods ending with 16 are very common and I don't think "18" rods exist. 6013 might be OK for sheet metal but there are better choices for anything thicker than 14 gauge. 6010 on DC or 6011 on AC can produce strong downhand welds. Uphand is still stronger but downhand is acceptable because it is a deep penetrating rod with a lighter flux and can be whipped back and forth to dig the arc in for more penetration. Most manual pipeline work is done with a fairly hot downhand 6010 using straight stringer beads and no or very little whipping. Pipeline welding is almost a seperate trade in itself. Going back to 6013, they can call it whatever they want but it's still just 6013. Not very often the rod of choice. Hope this clears things up for you. Dave

[Log in to Reply]  [No Email]
Stan in Oly, WA

09-02-2007 15:18:15




Report to Moderator
 Re: Welding Rods Question in reply to LM, 09-02-2007 14:27:41  
Hi LM,

Where do you live that you can only buy electrodes of two brands that most Americans have never heard of? Oerlikon is a Swiss company, isn't it?

Most 7018 rods run best on DC+. For AC welders it's probably best to buy 7018AC. I don't like it much, but my experience with it is quite limited.

Neither 7018 or 7016 are vertical down rods. 6013 and 6011 are both rated for vert. down and both run well on AC welders. 6011 would be my choice. It burns its own slag out of the way. If you can get a vert. down joint w/o slag inclusions using any kind of 6013, you're a better weldor than I am.

I don't know anything about "overcord" or "fincord". Personally, I find it very difficult to get good results with any brand or any size of 6013 regardless or polarity, amperage, or position. I've spent dozens of hours trying to figure out why I get slag inclusions with it sometimes and other times not, even thought the conditions seem identical. I wish it worked better for me because it's an easy striking, easy cleaning electrode---and I came into possession of hundreds of pounds of it at no cost a few years ago.

All the best, Stan

[Log in to Reply]  [No Email]
Doug N

09-02-2007 15:26:49




Report to Moderator
 Re: Welding Rods Question in reply to Stan in Oly, WA, 09-02-2007 15:18:15  
Hi Stan. You are right as to 7018 not being recomended for downhill. I don't want to start anything, but I have run 7018 downhill many times. I don't like to, but it can be done and it does hold. And yes it is a pain in the a$$ with the slag. But the trick is to back the rod off(away) just a little and your fine. Doug N



[Log in to Reply]  [No Email]
NC Wayne

09-02-2007 17:44:57




Report to Moderator
 Re: Welding Rods Question in reply to Doug N, 09-02-2007 15:26:49  
Don't remember when exactly it was but a few years back I read an article concerning the controversy on running 7018 rods downhill vs uphill. For years the thinking was you could only run them uphill but the gist of the article was that they could also be run downhill with no problem and no loss of strength. Personally I've always run them downhill and have never had a problem with either slag inclusions or lack of penetration, and more have never had anything I welded together break back loose. The main thing I've found is to get the amperage set right first and foremost. When that's right it's not that hard to keep the rod at a good angle for the job at hand and to keep it in close to the arc. This way the arc is strong enough to cause maximum penetration of the material and at the same time keeping the molten puddle cool enough that it doesn't drip out and sag. Typically the problems I see when welding downhill are caused by running the amperage too high. This causes the puddle to sag and also the flux to sag and run off the weld area, ending up down in front of the arc, before the area it should be covering cools. Just like welding uphill, doing it downhill takes practice. With that practice though, according to the article I read, welding downhill is supposed to be just as strong as a comparable weld done uphill. But then I'm not the expert, I'm only relying on my own experiences and the results of tests done by the people who's results were detailed in the article.

[Log in to Reply]  [No Email]
Doug N

09-02-2007 15:17:36




Report to Moderator
 Re: Welding Rods Question in reply to LM, 09-02-2007 14:27:41  
LM, alot of people are going to answer with whats best, and there will be alot of different ones.

I don't know metric too well but 3mm is thin. You'd be best off with a 3/32" 6010 or 6011. That you'd want to go down hill with.

Now I know 8mm is about 5/16", so 6mm is about 1/4". You could also use 6010 or 6011 in the 1/8" flavor. But you could also use 7018 uphill. Here's where the contraversy(sp) starts. DC or AC. I've been welding for about 25 years, and I do prefer DC. But I will say I have no problem with AC uphill or overhead. If you go with AC, get 7018AC rods.I've welded plenty of things with AC and is still holding.

Can't help you with 7016 or 6013 cause I've never used either before. Bottom line is what ever you're comfortable with , use.

Just my two cents. Doug N

[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy