jml755
06-07-2007 19:01:41
|
|
Re: automatic transfer switches in reply to supergrumpy, 06-07-2007 13:03:01
|
|
| |
Don't agree with the "mickey mouse" description of the manual xfer switches. I've got an 8500w generator and I installed a 6 circuit xfer switch. Took all of about an hour. Half of that time was finding a piece of plywood and power-nailing it to the basement wall. Got a box for the outside of the house and made up a 30' cord so I can put the generator in the back of the house out of sight, run the cord to the outlet by the meter, plug it in, then flip the xfer switches. The 6 circuits will run lights in every bedroom(4), bathroom(3), furnace, 2 refrigerators, living room, kitchen. In other words, enough to get by until the power company gets the power back on. I seriously considered the stationary units powered by natural gas and the auto xfer switch. They ARE nice (test themselves once a week), but cost probably 3-4 times what I've spent on my setup. Used to lose power 2-3 times/year, once or twice for any extended period. Since I've got the generator: no outages yet. (LOL, Murphy's Law in reverse). Anyway, figure out what you need and what you want to spend, then go for it. If cost is not a consideration, definitely go for the peace of mind and the whole house unit. If you know basic electrical wiring and don't freak out when the circuit breaker panel cover is off, you should be able to put in a manual switch. Read the instructions and by all means, kill the main breaker when working in the panel.
|
|
|