Running multiple alternators to charge one battery

Welcome Guest, Log in or Register
Author 
IH2444

02-20-2007 07:42:10




Report to Moderator

I am going to hook up a couple of golf cart batteries to run inverters for a camper trailer.

I would like to hook up a pair or 130 amp alternators to a small (approx 18-20 hp)engine to charge the batteries with.

Has anyone hooked up multiple alternators to the same battery ?




[Log in to Reply]   [No Email]
Oldmax

02-21-2007 17:28:01




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to IH2444, 02-20-2007 07:42:10  
I can't Figure what would pull 200 Amps that anyone would use while camping . Most campers with 1 A/C are 30 amps & with 2 A/C are 50 amps . A 3000 Watt Gen Set will run 1 A/C . If you are going to try to run a A/C off a battery through a inverter Forget it Batterys won't take charging and discharging with out damage.



[Log in to Reply]  [No Email]
Bob

02-21-2007 19:13:03




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to Oldmax, 02-21-2007 17:28:01  
I think he's talking about 200 Amps @ 12-Volts to POWER the inverters.



[Log in to Reply]  [No Email]
Dave in Tx

02-21-2007 05:31:03




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to IH2444, 02-20-2007 07:42:10  
130 amp alternator running at full load will work the snot out of a 20 hp engine. BTDT



[Log in to Reply]  [No Email]
dave guest

02-20-2007 19:16:25




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to IH2444, 02-20-2007 07:42:10  
I think slower the charge and charge rate, the better for the batteries. Don't want to buckle the plates and short out internally. Make sure batteries can handle this setup.



[Log in to Reply]  [No Email]
RayP(MI)

02-20-2007 18:20:20




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to IH2444, 02-20-2007 07:42:10  
Due to the problems listed below, it might be tough to parallel the alternators. Why not just get a bigger alternator? Some of the simpler alternators can be upsized with a field coil with more windings. I did that once in a car that came with minimum alternator, and I wanted more electricity to provide for 2-way communications gear. Last time I had my truck alternator worked on, asked the shop man if it could be "biggie sized" - he reached over on the shelf and handed me another unit. visually identical, excepr for extra cooling holes in the side of the case. By the way, I built just what you're planning to do with a tired (retired) 5hp tiller motor, and a single 60amp Delco. Works fine, and full load will make the engine grunt a little. Also, you have to gun the engine at startup to get the alternator to start producing electricity.

[Log in to Reply]  [No Email]
Charles (in GA)

02-20-2007 18:04:24




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to IH2444, 02-20-2007 07:42:10  
If the alternators run external regulators, use one regulator to control the field of both alternators together. This is the way it is commonly done in twin engine aircraft. If you use two alternators with two separate regulators (and there are twin engine aircraft that do this) you need a paralleling unit to keep the two alternators together, otherwise the one that runs the slightly higher voltage will win out and the other unit will not produce any amps until the higher unit becomes overloaded and can no longer keep up. (and no two regulators, internal or external will run perfectly together).

Charles

[Log in to Reply]  [No Email]
Allan In NE

02-20-2007 09:45:22




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to IH2444, 02-20-2007 07:42:10  
Sure,

Just like the air compressors. The system is gonna take only what it demands.

The Powerstrokes started running twin alternators many years ago. Would imagine other makers did likewise.

Allan



[Log in to Reply]  [No Email]
Ih2444

02-20-2007 09:51:15




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to Allan In NE, 02-20-2007 09:45:22  
Thanks,
That is what I figured, just had not done it before.



[Log in to Reply]  [No Email]
Jon Hagen

02-20-2007 10:25:27




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to Ih2444, 02-20-2007 09:51:15  
a few years ago,the 90 amp factory 1 wire alternator on one of my Steiger 4X4 tractors finally died from years of field dust clogging the cooling passages, a replacement for this off brand odd ball was $400,which I was not willing to pay when I could assemble a 1 wire 10SI Delco for $35 that fit right on the original mount. This worked Ok with a 72 amp stator, but was a little weak at low rpm and generated too much heat for dirty conditions with the stock cooling fan and passages. The engine has an unused accessory pulley, so I mounted a second 1 wire 10 SI with only 61 amp stators installed in both alternators. This has worked great, with 30 more amps than stock, the alternators keep ahead of the load even at idle and each alternator cooling system having to cool only a 61 amp alternator. They share the load evenly judging by feeling of stator frame heat while running. The total cost was less than 1/4 of what a single stock alternator would cost, with the side benifit of having more output than stock and twice the cooling capacity. Another advantage showed a few years later when a bearing failed in one of the dual alternators, I just removed the drive belt from the broken alternator and finished the day with the remaining one doing the job with the reduced electrical load of running in daylight.

While the dual alternators work fine hooked in parallel, the problem is that you can't fast charge deep cycle batteries as others have stated. You would need a very large bank of deep cycle batteries to safetly absorb several hundred amps of 12V power. You could run the engine/alternators at reduced speed so as to not charge the deep cycle batteries to fast,with the option of increasing the speed/output when the inverters are on and drawing high anps from the alternators instead of the batteries.

[Log in to Reply]  [No Email]
Ih2444

02-20-2007 11:57:22




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to Jon Hagen, 02-20-2007 10:25:27  
thanks Jon, I have training and experience on lead acid abttery charging for telephony systems. I understand charging rates, equalize and float charge voltages, specific gravity and such. For charging I would shut off all but one 60 amp alternator. The golf cart batteries will handle that as it is regulated voltage, unlike a fast charger in a shop.
I also have 12v vent fans in the battery area of the camper to vent the fumes.
I also have a couple of 400 amp shunts for measuring charge and discharge current.

My only question on the whole project was about hooking the outputs of alternators together. In theory I thought it would work, but had never tried it.

[Log in to Reply]  [No Email]
Jon Hagen

02-20-2007 14:33:52




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to Ih2444, 02-20-2007 11:57:22  
Sounds like what you are building should work like the neat inverter generators sold by Honda and others, where a gas engine turning a DC generator runs just fast enough to meet the inverters needs for a given AC load. Using your larger engine at less than full load and rpm should make for a lot less noise and low fuel consumption, with long engine life and little chance of overheating if air cooled.

[Log in to Reply]  [No Email]
ScottP

02-20-2007 09:04:31




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to IH2444, 02-20-2007 07:42:10  
IH2444
You would be better off with a deep cycle battery charger of the correct voltage and a small genset.
Less fuss and quieter to run and cheaper in the long run. An 18-20 hp engine will go through the gas for what you would be getting in return.
Scott



[Log in to Reply]  [No Email]
Ih2444

02-20-2007 09:41:40




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to ScottP, 02-20-2007 09:04:31  
Umm how would I keep the inverters going without the alternators ? they are not just for recharging, but for running. Kinda hard to pull 200 amps out of a battery for very long. And no commercial ac will be available for the camper.



[Log in to Reply]  [No Email]
ScottP

02-21-2007 09:15:19




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to Ih2444, 02-20-2007 09:41:40  
IH2444
Simple. Plug the battery charger into the genst hook charger to batteries. Hook inverter to batteries. Start genset when batteries are charged shut off genset.
The inverter doesn't care how the batteries are charged. You can get an inverter with a charger buildt in. I have 3 myself, that I use on my power station. You can run a charger off a 4000 watt genset with an 11hp engine longer than a 20hp with two alternators, much simpler also. As far as pulling 200 amps I run my whole house off batteries and never pull that much power. I think you need to check you trailer for a ground or short if you pull that many amps. I think you are confusing having a 200 amp service with actual amps used or required.
Scott

[Log in to Reply]  [No Email]
NEsota

02-20-2007 08:21:57




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to IH2444, 02-20-2007 07:42:10  
Not me, have not done that or got the tee-shirt but a 260 amp charge is probably too much instant gratification for these batteries. You may want to think smaller as far as charging capacity is concerned.



[Log in to Reply]  [No Email]
Gerald J.

02-20-2007 08:14:30




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to IH2444, 02-20-2007 07:42:10  
Just a couple golf cart batteries wouldn't appreciate (or survive long) 250 amps charging. Eight might be a better quantity.

130 amps 14 volts is only 1820 watts, take maybe 3 or 4 hp to generate. Two alternators won't make much of a load for that 18 hp engine.

But without some extra engineering and modifications or delicate manual adjustments on the regulators the two alternator won't share the load equally.

It would work better to find a large truck alternator with more capability than your pair of 130 amp alternators. Or to use a normal 120 volt AC alternator and a large battery charger.

Without special control circuitry, the 130 amp alternator won't charge at full rate while its voltage regulated at 14.2 volts. It will charge at that rate when the battery is nearly dead but will taper off towards zero as the battery takes charge. So the big engine won't be worked hard for most of the charging period.

There is a smart charger available for RVs that will charge at a higher rate until the battery is about 80% charged then change to the constant voltage 14.2 volts for finishing and floating. It makes better use of the charging by gasoline power.

Gerald J.

[Log in to Reply]  [No Email]
Ih2444

02-20-2007 09:45:56




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to Gerald J., 02-20-2007 08:14:30  
Umm guys I am planning on running the alternators while I draw about 200 amps out of the batterys. this is not a fast charge thing, but more of a running thing. I will have a slow charger back at the barn to keep the batteries topped off while the camper is idle.



[Log in to Reply]  [No Email]
T_Bone

02-22-2007 02:56:34




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to Ih2444, 02-20-2007 09:45:56  
I got to agree with Gerald as to what are you planning on doing with the 18000btu/hr your (yep that's 18000) going to create between a discharge/recharge cycle of the batteries?

With the newer PWM regulation you might get close to a 60% recharge before thermal automatic shut down occurs on the regulator.

Altough the T105 batteries are rated at 105a/hr each at 6v, that's also true at 12v@105a/hr. Four T-105's would yield 210a/hrs of battery at 12v.

Of the cheaper 1200w invertors on the market, they run 100% rated input watts no matter what the load demand. The more expensive 1200w invertors have the varible input demand controls but were talking $800 vs $200 for each invertor.

The above is some of the considerations I ran into thinking along the same project scope a few years back.

If your wanting AC while boondocking, have you considered using a liquid/air heat exchanger? Here you would just have a small water circulating pump and fan for cooled air. Chilled water could be from a stream/lake/well or a water bed matteras used as a temporary holding tank under the RV. A hand driven water well can be easy installed for a cheap cost, under $50, in alot of places.

T_Bone

[Log in to Reply]  [No Email]
Bob

02-20-2007 08:06:35




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to IH2444, 02-20-2007 07:42:10  
Yes.

There's 2 engines in my snowblower, each with a Delco 10SI alternator, charging one battery. Not much different than if they were driven by the same engine.



Third Party Image

Allis used 2-alternator setups on their combines for more electrical capacity.

Some ambulances and HD pickup trucks have dual alternator setups.

[Log in to Reply]  [No Email]
Kent in KC

02-20-2007 08:04:16




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to IH2444, 02-20-2007 07:42:10  
Nope, interesting idea. Maybe a bad idea, too. Wouldn't that be like pumping 24V into a 12v battery?



[Log in to Reply]  [No Email]
Bob

02-20-2007 08:07:50




Report to Moderator
 Re: Running multiple alternators to charge one bat in reply to Kent in KC, 02-20-2007 08:04:16  
No, not unless he manages to connect the alternators in SERIES.



[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy