Joe in Minnie

08-06-2005 11:18:58




Report to Moderator

Hi Tractor Friends, I have a IH240 Utility, and I find that the Gas Gage is not hooked up.. Can any one tell me where the TWO Posts on the Gas Gage get's hooked up. I would assume that one would be hooked to the Tank sending unit, and the other, well, not sure at all. These Tractors have Positive Ground, which I sure would like to know why "back then" they made Tractors with Positive Ground, seems odd to me.. Thanks for your help.....Joe any way, can anyone give me some good advise ?

[Log in to Reply]   [No Email]
tech4

08-06-2005 15:53:03




Report to Moderator
 Re: Electrical Question in reply to Joe in Minnie, 08-06-2005 11:18:58  
The gas gauge and the tank unit should be connected in series as has been mentioned. Most vehicle systems used a constant volt regulator that put out a constant 5 volts so the gauge would not vary with changes in battery voltage and generator/alternator charging circuit.
Positive ground systems were a carry over from telephone and telegraph systems that used positive ground (telephone company today still uses positive ground) because there was less corrosion due to minerals in the earth with a positive ground. Later the experts discovered that it made no difference in vehicles because the chassis was insulated from earth ground by the rubber tires and corrosion was not a problem. See link below for a little history on positive ground..

[Log in to Reply]  [No Email]
MarkB_MI

08-06-2005 19:20:58




Report to Moderator
 Re: Electrical Question in reply to tech4, 08-06-2005 15:53:03  
Tech,

That was an interesting link. Thanks for posting.



[Log in to Reply]  [No Email]
hawaiirocky

08-06-2005 17:45:35




Report to Moderator
 Re: Electrical Question in reply to tech4, 08-06-2005 15:53:03  
I've asked this question since I was a kid back in the fifties, and this is the first I've heard it answered. I'll win a couple of beers over this one. Thanks.



[Log in to Reply]  [No Email]
Sam#3

08-06-2005 15:07:02




Report to Moderator
 Re: Electrical Question in reply to Joe in Minnie, 08-06-2005 11:18:58  
A fuel gauge system is usually a series circuit consisting of a potentiometer(sender) and an ammeter. One end of the pot. will be connected to the frame ground(tank and bonding) the other will connect to the one side of the meter. The other side of the meter will connect to a source of switchable battery. Don't connect to a hot lead.
The meter is one of the few things that is polarity sensitive on these machines. If it reads backward reverse the meter leads.

[Log in to Reply]  [No Email]
RustyFarmall

08-06-2005 13:27:44




Report to Moderator
 Re: Electrical Question in reply to Joe in Minnie, 08-06-2005 11:18:58  
At one time positive ground was considered to be state of the art. Most all motor vehicles used this technology right up into the 40s and maybe early 50s. It wasn't until Chrysler introduced the alternator charging system in the early 60s that negative ground became the industry standard. It just took the ag industry awhile longer to change over.



[Log in to Reply]  [No Email]
old

08-06-2005 13:07:40




Report to Moderator
 Re: Electrical Question in reply to Joe in Minnie, 08-06-2005 11:18:58  
One side goes to the gauge and the other side would go to the switch on the side of the switch that is only hot when the key is on. As far as + ground thats just the way it was done back then some thing about how they thought things worked I think.



[Log in to Reply]  [No Email]
Illinois Boy

08-06-2005 13:20:09




Report to Moderator
 Re: Electrical Question in reply to old, 08-06-2005 13:07:40  
Seems like I recall an electrical shop class where the teacher said some people teach that positive flows to neg (neg ground) and some people teach neg to positive (pos ground)
I guess that's why it's called the "theory" of electricity...



[Log in to Reply]  [No Email]
Sam#3

08-07-2005 19:07:04




Report to Moderator
 Re: Electrical Question in reply to Illinois Boy, 08-06-2005 13:20:09  
This whole thing drove me to the textbook. From the book "Basic Electronic" by Bernard Grob, Mcgraw-Hill, 1989.
In sub-chapter 1-9 'Direction of current flow' I quote select entries: 'Electron flow.' "The direction of electron drift for the current I* is out of the negative side of the voltage source."
"Inside the battery*, the electron move to the negative terminal because this is how the voltage source produces its potential difference." (*refers to a figure)
'Conventional Current' "The motion of positive charges, in the opposite direction from electron flow, is considered conventional current. (Skipping a couple lines.) "By the definitions of force and work with positive values, a positive potential is considered above a negative potential. Then conventional current corresponds to the motion of positive charges "falling downhill" from a positive to a negative potential. The conventional current, therefore, is the direction of positive charges in motion."
The writer goes on the mention the convention current flow was used in the marking of diode and transistors and all semi-conductor devices.
After reviewing this text I can remember covering both but the conventional current was just dropped and forgotten.
With all that said it still doesen't explain the terms pos. or neg. grd. Why not pos. or neg. bat?

[Log in to Reply]  [No Email]
T_Bone

08-07-2005 03:22:28




Report to Moderator
 Re: Electrical Question in reply to Illinois Boy, 08-06-2005 13:20:09  
Hi IB,

DC resistive circuits use negitive to positive flow therory and DC semi conductor citcuits use positive to negitive flow therory.

Had the guys back in the 1940's never reversed there thinking to positive to negitive flow, the semi-conductor would have never been invented.

T_Bone



[Log in to Reply]  [No Email]
txgrn

08-07-2005 07:13:17




Report to Moderator
 Re: Electrical Question in reply to T_Bone, 08-07-2005 03:22:28  
In tech school they taught me electron flow. Since an electron is neg it is attracted to a positive charge hence - to + "current flow".

In college, they taught me the "hole" created by the moving electron. Since the electron was going as mentioned, the hole, or absence of the electron (that just moved) went + to -.

Since most power supplies used with Silicon transistors and other electronic ckts (T-Bone mentioned)of today are + (bias supplies -), it is easy to come out of the + node of the power supply and distribute your power, in your design, to the needy circuits.

In trouble shooting circuits I found that the former was easier so the tech school training prevailed.

In designing the latter was easier and since colleges teach you to design, you are exposed to the hole theory.

So in talking "shop" with someone, the first thing you have to do is to find out what theory they are using in their conversation.

My 2c,

Mark

[Log in to Reply]  [No Email]
James L. Babcock

08-07-2005 08:20:00




Report to Moderator
 Re: Electrical Question in reply to txgrn, 08-07-2005 07:13:17  
I was taught somewhere in the past that the + and - terminology was "invented" by Ben Franklin and he had a 50/50 chance of getting them "correct". Well, actually the + pole on a battery is the source of electrons and thus should have been called the negative pole if only ol' Ben hada known that an electron is considered to carry a negative charge. It's way too late to "correct" Ben's theory, and it really doesn't make a lot of difference in running an old tractor. Perhaps this is why the semiconductor boys and girls use the theory that current flows from + to - since that is actually the path that the electrons take.

[Log in to Reply]  [No Email]
txgrn

08-07-2005 17:14:38




Report to Moderator
 Re: Electrical Question in reply to James L. Babcock, 08-07-2005 08:20:00  
Matter of elementary physics: atoms, protons, neutrons and electrons. The electron has the - charge and when in the valence outer ring of the atom, and loosely bound, like in copper, silver, gold, aluminum etc.it is easily dislodged by a + charge and "flows". This movement is measured in Coulombs per second (amperes) and is commonly known as charge transfer or current flow.

Mark



[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy