I was given a furnace blower to use in my shop. It had already been set-up with a pig-tail plug attached to the two wires coming out of the motor. When I plugged it in, it ran very well for just a few minutes and then I heard a click and it stopped. I unplugged it, and then found the motor so hot I couldn't lay my hand on it. After a few minutes, I plugged it back in, it ran for a while and again quit. The motor is a dedicated duty, rather than continous duty, and there does not appear to be any way to wire it differantly, other than to reverse rotation. Short of replacing the motor, is there any way I can make this thing work?

[Log in to Reply]   [No Email]
buickanddeere

08-04-2004 05:06:51




Report to Moderator
 Re: furnace blower in reply to rustyfarmall, 08-03-2004 08:14:45  
Covering the non motor side of the inlet is the most efficient method. Use a clip on ammeter to adjust until full load amps is achieved.



[Log in to Reply]  [No Email]
rustyfarmall

08-03-2004 14:28:15




Report to Moderator
 Re: furnace blower in reply to rustyfarmall, 08-03-2004 08:14:45  
Thanks to all of you folks, I held a small piece of pegboard over the discharge side, covering about 1/2 of it. I need to make something a little more permanent, but I think that is going to fix it. Also cuts down on the noise, which is a big plus.



[Log in to Reply]  [No Email]
Ohio-Bob

08-03-2004 13:39:41




Report to Moderator
 Re: furnace blower in reply to rustyfarmall, 08-03-2004 08:14:45  
I had the same problem. I built a plywood box, set the blower unit inside the box, with a exhaust port, and also a controled intake port (hole in top of plywood, with a slide ) that lets the air flow over the motor, and your problems are gone.



[Log in to Reply]  [No Email]
rustyfarmall

08-03-2004 14:29:34




Report to Moderator
 Re: furnace blower in reply to Ohio-Bob, 08-03-2004 13:39:41  
Bob, I like that idea.



[Log in to Reply]  [No Email]
Chip

08-03-2004 11:58:24




Report to Moderator
 Re: furnace blower in reply to rustyfarmall, 08-03-2004 08:14:45  
Smaller blowers are usually shaded pole,no cap.The blower is overloaded,block about 1/2 the intake opposite the motor,it will speed up & move more air.You don't need to do anything with the outlet.



[Log in to Reply]  [No Email]
Bob

08-03-2004 12:16:45




Report to Moderator
 Re: furnace blower in reply to Chip, 08-03-2004 11:58:24  
Partially blocking the outlet will restore the fan to the operating condition it was designed for, which was working with the restiction provided by the furnace and ductwork.

Blocking the inlet MAY be more likely to affect the movement of cooling air around the motor, and may cause side thrust loading on one of the motor bearings, and is unnecessary.

Most modern furnace fan motors ARE capacitor run, for efficiency. It seems like mobile home furnaces had shaded pole motors long after residential furnaces had gone to capacitor run motors.

[Log in to Reply]  [No Email]
Chip

08-03-2004 15:37:28




Report to Moderator
 Re: furnace blower in reply to Bob, 08-03-2004 12:16:45  
I'm not into a p***ing contest today,sorry.You're right,most modern motors are.And most brands,especially low end,small -1/12 to 1/4hp still use shaded pole.Some blowers come with an adjustable inlet cover and there is usually duct/filter restriction. Its called the 'return'.Bearings? Usually bushings,unoilable at that.Just MOO,having BTDT. I'm over 40,born (3rd gen)in the business,don't know all of it,still learning.

[Log in to Reply]  [No Email]
rustyfarmall

08-03-2004 11:31:20




Report to Moderator
 Re: furnace blower in reply to rustyfarmall, 08-03-2004 08:14:45  
Hey, thanks guys, restricting the output would never have crossed my mind. It does make sense though, when the blower was still in the furnace, it had a lot of ductwork to push that air through, thus a lot of resistance. I will experiment later, and post again with the results.



[Log in to Reply]  [No Email]
MAC,IL

08-03-2004 11:00:56




Report to Moderator
 Re: furnace blower in reply to rustyfarmall, 08-03-2004 08:14:45  
I had an old furnace squirrel cage I used in the shop, it had the same symptoms you describe. I covered one side(opposite the motor) of the cage opening and solved the problem. Evidently there was not enough restriction OR there was not enough air coming in over the motor. Anyhow it worked fine after that.



[Log in to Reply]  [No Email]
Bob

08-03-2004 08:21:40




Report to Moderator
 Re: furnace blower in reply to rustyfarmall, 08-03-2004 08:14:45  
If it is a typical centrifugal fan, the motor is sized to reflect some air flow resistance on the output of the blower.

If you run it in free air, not connected to the furnace and ductwork, the motor will be overloaded.

Hold a piece of plywood, or whatever, against the output side to restrict the airflow, and go will notice the unit speeding up, from the decreased load on the motor. Peramanently attach your restriction to the OUTLET side of the fan, and post back with your results, please!

[Log in to Reply]  [No Email]
Jay (ND)

08-03-2004 11:00:10




Report to Moderator
 Re: furnace blower in reply to Bob, 08-03-2004 08:21:40  
Bob is right on the money for the first, easiest, and cheapest place to start. The blowers won"t last without resistance.



[Log in to Reply]  [No Email]
john in la

08-03-2004 08:26:53




Report to Moderator
 Re: furnace blower in reply to Bob, 08-03-2004 08:21:40  
I like using a old licence plate off a car. You can bend it around the sides and hold it in place with sheet metal screws.
Cover about half of the opening and see how it does.



[Log in to Reply]  [No Email]
T_Bone

08-03-2004 09:40:14




Report to Moderator
 Re: furnace blower in reply to john in la, 08-03-2004 08:26:53  
Hi Rusty,

Are you sure your not missing a run capicitor? Should be a 5mfd or 7.5mfd on the two brown leads. Should have the cap rating on the plate.

Usually the stack rating will not have a effect on a motor as long as it's running inside a fan housing.

T_Bone



[Log in to Reply]  [No Email]
Larry in Tn

08-03-2004 18:06:17




Report to Moderator
 Re: furnace blower in reply to T_Bone, 08-03-2004 09:40:14  
Maybe a little out of left field but a stuck starter winding contact will cause similar havoc depending on the type of motor. I have a furnace blower unit that I use to move air in my garage when I'm casting bullets. So far I've not used any type of resticter on it. It work's OK.



[Log in to Reply]  [No Email]
MPK

08-03-2004 19:04:35




Report to Moderator
 Re: furnace blower in reply to Larry in Tn, 08-03-2004 18:06:17  
In the experience I've had, with the fan unrestricted, you need about twice the size of motor than it had in the furnace. You can either restrict it, put smaller pulley on motor, or use bigger motor.



[Log in to Reply]  [No Email]
Rick

08-04-2004 15:56:47




Report to Moderator
 Re: furnace blower in reply to MPK, 08-03-2004 19:04:35  
I have one of those units out of a furnace I don't need anymore and it works fine just old if anyone is interested in it. Sell cheap



[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy