Welcome! Please use the navigational links to explore our website.
PartsASAP LogoCompany Logo (800) 853-2651

Shop Now

   Allis Chalmers Case Farmall IH Ford 8N,9N,2N Ford
   Ferguson John Deere Massey Ferguson Minn. Moline Oliver

Attention Forum Users: On the 28th of December 2023 at 9:00am Central Time, we will be taking the forums down for maintenance while we prepare the new forums for your use. Please click here for more information.

Tool Talk Discussion Forum

SuperWelder***** Where Art Tho?

Welcome Guest, Log in or Register
Author 
T_Bone

01-26-2004 04:13:13




Report to Moderator

Hi All,

Last week I was doing some research and seen and couple management trends that I thought would be interesting to the new welders and welders that want to stay competitive in the trades that management considers normal until 2020.

FCAW (flux cored arc welding) is what there pushing toward converting all SMAW (stick welding) processes. Why? 30% faster even when considering the extra machine set-up time by having to drag the feeder head around. They even included man hour fatigue time for such. According to the study, the cost projections can be pushed close to 80% savings by increasing typical 200amps FCAW current too 300amps and that it's self brings new problems to the table.

What I didn't read about in the study is the eye and attention span fatigue that comes along with using FCAW with longer weld times between resting. I believe this will be the down fall for production type of manual FCAW. I don't believe these two conditions has been considered enough, if at all, as they were not mentioned in the articles.

The short time it takes to change electrodes in SMAW is enough time for a good man too over come attention and eye fatigue using 1/8" electrodes at approx 130amps. What suprised me was the deposition rates of the study at 6lbs/hr using 7018. To burn 50lbs of 7018 in one 8hr day, one would have to be flat humping but yet this was considered "normal" in the study.

Makes me wonder where all the "superwelders" will come from to meet there projections for 2020.

T_Bone

[Log in to Reply]   [No Email]
Buck

01-28-2004 17:41:22




Report to Moderator
 Re: SuperWelder***** Where Art Tho? in reply to T_Bone, 01-26-2004 04:13:13  
Hi T_Bone here is the info you requested. I did a job about 100 years ago right up by the Canadian border, for the Alaska ferries system. It was a steel dock with precast concrete deck panels. The panels had galvanized angle iron embeds in them, the panels would set down on the structural galvanized beams then required 1/2" fillet 6 on 12. The only inspection was visual, but the guy was a real peach, 1/2" did not mean 31/64". So we tried to go as fast as we could, but still make the weld with one pass. I had my machine rented to the company, I would have someone look at the amp gauge on the power source, and wire feeder. At times 550 to 575 amps. We were running a wire made by Hobart, 21-B 5/64" This wire was wonderful on galvanized material. These galvanized docks are real popular in Washington and Alaska. We were working 4-days a week 10-hours a day. I could run (5) 14lb rolls of wire everyday, Now the only time you got a break was when you had to move, change rolls, or lay out for the 6 on 12. My company did not allow coffee breaks, just 1/2-hour for lunch! Talk about having to have a strong back. The deck panel were about 16-inches thick and the angle embed was at the bottom. Let me tell you, we were tired puppies at the end of the day. We also ran a lot of Lincoln's NR-211MP, NR-232, NR-302N. Almost always the 5/64" wire, When I got into the position were I was calling the shots, I would buy .068 wire for the guys if they were running a lot of vertical. Little less metal to keep track of. Around here the caliber of welders has really fallen off. I fired a certified welder a few years ago for telling me that polarity did not mean anything, it was just a wives tale. On 99% of the docks, the deck panels have # 12 rebar exposed, the panels would be placed end to end and have about a 4-inch gap between the rebar. Then you would slap a 16" piece of 4 x4 x1/2 angle iron under the rebar and weld in 4 location, now the Iron Workers claim this when it's rebar. They almost always bring LN-8, or LN-9, don't have to change wire so often with them suckers!

[Log in to Reply]  [No Email]
Bill 52 8n

01-28-2004 10:09:02




Report to Moderator
 Re: SuperWelder***** Where Art Tho? in reply to T_Bone, 01-26-2004 04:13:13  
T-Bone

In school they push FCAW on us as the next big thing in production operations. Adding to the advantages you listed, you get deeper penetration with less amps compared to solid wire because the FCAW is a tube and takes less heat to melt it and the powder metal inside. Also you can use steeper angles on bevels compared to SMAW, we used 45 degrees for FCAW, 60 degrees for SMAW. Steeper angle allows you to weld the same two pieces of metal together faster with less passes.

Bill

[Log in to Reply]  [No Email]
Wayne

01-26-2004 20:02:33




Report to Moderator
 Re: SuperWelder***** Where Art Tho? in reply to T_Bone, 01-26-2004 04:13:13  
Hey T-Bone, I think the reason they want to go to FCAW for the higher deposition rates as compared to SMAW is that most of the newer generation is so lazy when it comes to really wanting to work, that the only way they'll ever get 50lbs of weld a day out of anybody is if they make it easier on them. Also wire welding, of any type, is usually easier for people to learn than stick, so it won't take as long to train the new guys. On a more serious note, look at the new trend of minature, briefcase size inverter power supplies where you have short leads and a drop cord -vs- dragging 2 500' lengths of lead around all day. That in itself should make a big difference in the production capacity of one man just using SMAW. Then add to that the fact they are also making suitecase wire feeders that can be powered off either a CC or CV power supply. Team up the two and you have the makings of a very productive setup. I understand what your saying about the fatigue factor, but if you look at deposition rates for SMAW which I've always heard is about 50%, by weight, and either FCAW or GMAW which closer to 90-98%, by weight (depending on wire type, and arc/transfer type, etc) then fatigue shouldn't really be a problem. In all actuality the operator would only have to work just over half as much to lay down the same amount of weld using FC/GMAW as he would doing it with SMAW. To me this means more breaks and less work for the same amount of output. It also means less time and effort exerted flipping the helment up (for those of us that don't really like the self darkening lenses)and less effort exerted nodding it back down. I'd much rather be able to run a clean 6'bead without stopping than to have to start and stop several times to change rods. It just makes for a cleaner looking weld as well as less chance for porisioty, etc every time you have to reestablish the arc. Personally I have a Miller Trailblazer on my service truck and a feeder with a 14 pin connection to hook up to it. I have tried the flux cored stuff, but have found I can get just as good a results using 75/25 gas shield, even in the field. The only time it creats a problem is if it's really windy out, but even then it usually isn't that hard to set up a wind block and keep right on going. As far as time savings is concerned,I did a job in the field Friday that would have taken me most of a day if I had been trying to stick it. It was mostly 1/4 inch material with wide gaps, in odd positions, which would have been a real pain in the a$$ to fill using a stick. With the feeder and .045 wire I was done in about 3 hours. I guess there are pros and cons to each process, but in this case I think the pros far outweigh the cons....As for the team that did the study though, like you I think their numbers are a bit unrealistic. Just my .02

[Log in to Reply]  [No Email]
SHeiserman

01-27-2004 19:28:26




Report to Moderator
 Re: Re: SuperWelder***** Where Art Tho? in reply to Wayne, 01-26-2004 20:02:33  
Put a good fitter out in front, and a guy could go like he!! all day long, regardless of which method is used. Seems to me good fitters are harder to come by than weldors. As long as there are people out there who don't know how to find center of a circle (flat sheet stainless), or hand cut a bevel with a torch or plasma, it's only going to be so fast. A talented fitter/weldor combo can get alot of work done with an old oxy acetylene torch and stick welder.

[Log in to Reply]  [No Email]
T_Bone

01-27-2004 01:59:05




Report to Moderator
 Re: Re: SuperWelder***** Where Art Tho? in reply to Wayne, 01-26-2004 20:02:33  
Hi Wayne,

You got that right as even back 30yrs years ago, slackers were easy to come by. I also agree that Mig has always apperaed to be easy to learn as it's easy to make that first weld look like the other guy thats been laying them in for many moons, that is until they test the new weld and it easy falls apart.

Both GMAW and FCAW easy reach 100% of deposition rates when comparred to SMAW and that is what I was basing my opinion on. It's been said that the human acute attention span is only a couple minutes at best then deteriates from there. Granted this is just an average and there's lots of room to interput for whats average.

I forgot all about there comments on autodarken welding hoods until you mention them. They thought very highly of autohoods. I mean gees it takes 2 seconds to flip a manual hood and if the typical welder fliped there hood a 100 times a day that would be awhole 3 minutes saved per day.

There again there wasn't a comparrision from eye fatigue caused by the autodarken hoods. This is one point that I will never by in any study about the autodarkening helments as I still have to point out what comes first to make the auto hoods work, "the arc strike". The eye is very fast and they will never be able to build a switch thats faster than the human eye and that leads only to one thing, flash burn.

Don't get me wrong, I'm not just strickly a SMAW fan and realize theres a time and place for every welding process. With the CC/CV power supplies available today this makes having a process choice available much easier than it was 30yrs ago.

T_Bone

[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy