Tool Talk Discussion Forum

Wiring 120v/240v Elec Water heater

Welcome Guest, Log in or Register
Author 
Jim Petro

08-25-2003 18:02:03




Report to Moderator

Just had an A.O. Smith Model EES-52-100 water heater installed by my plumber. He wants me to wire it. I've installed basic 120v lighting & receptacle circuits from fixture to panel. Is this something as simple as buying a 240v breaker & routing some 12/2 wire to the heater? What rating is required on the breaker? The spec sheet lists two sets of numbers for the element wattage... 4500 & 6000 @ 240v.

[Log in to Reply]   [No Email]
David Bacon

09-04-2003 20:15:26




Report to Moderator
 Re: Wiring 120v/240v Elec Water heater in reply to Jim Petro, 08-25-2003 18:02:03  
You must remember regardless----you must fill with water before turning on the power or you will learn a lesson on replacing the units. It will burn out faster than lighting. I have rewirred water heaters in large consumption households to run both units at the same time. It takes the same amount of electricity, just lets you hit the ground running when it is needed. Good luck Dave NE Iowa



[Log in to Reply]  [No Email]
steve

09-05-2003 04:53:50




Report to Moderator
 Re: Re: Wiring 120v/240v Elec Water heater in reply to David Bacon, 09-04-2003 20:15:26  
David, You said wiring 120 vs 240 takes the same amount of electricity, unless I mis understood you this is not true, everyone knows 240 volts takes less power to run a utility than 120,



[Log in to Reply]  [No Email]
David Bacon

09-05-2003 20:16:39




Report to Moderator
 Re: Re: Re: Wiring 120v/240v Elec Water heater in reply to steve, 09-05-2003 04:53:50  
Steve, I may be wrong but Electric power 240 or 115 for say a motor will take exactly the same amount of power only advantage is the wire feeding it is providing 1/2 on each leg. Thus a smaller wire can be used. Now I must say you are not the first to question this. But look at a plate on any 115 / 240 motor--- the amps are exactly the same. If you take the 115 leg and divide it by 2---you have two legs remember on 240--- this will be exactly the same as the 115 amp rating. I tell many to grab the one handle of the wheel borrow, I will grab the other handle, the amount of push on each handle is the same. Steve I certiany do not want to come across as a smart butt, and perhaps like I said--I could be wrong. Dave NE Iowa

[Log in to Reply]  [No Email]
Hank Hill

08-28-2003 17:32:14




Report to Moderator
 Re: Wiring 120v/240v Elec Water heater in reply to Jim Petro, 08-25-2003 18:02:03  
Propane!



[Log in to Reply]  [No Email]
john

08-28-2003 01:24:19




Report to Moderator
 Re: Wiring 120v/240v Elec Water heater in reply to Jim Petro, 08-25-2003 18:02:03  
amps times voltes = watts so watts/ volts= amps
6000amps / 240 volts = 25 amps going with a 30 amp breaker will be fine. you need 10 gauge wire for a 30 amp circuit-- get 10-2 with a ground.you hook the black wire to one side of the breaker and the white wire to the other side and the bare wire to the ground bar in your elec box. in heater you hook bare to ground and the other two to the hot terminals per heater instructions.

[Log in to Reply]  [No Email]
Charles(Mo)

08-26-2003 18:36:28




Report to Moderator
 Re: Wiring 120v/240v Elec Water heater in reply to Jim Petro, 08-25-2003 18:02:03  
Listen to Busdriver. I have never heard of a waterheater wired with 8 ga. wire. Check the owners' manual. I am sure #10 ga. wire on a 30 amp breaker is what you will need.

If you have any doubts, contact your electric power company. I am sure they have a Member/Customer Relations Dept. that will answer any questions for you.



[Log in to Reply]  [No Email]
Bus Driver

08-26-2003 05:02:29




Report to Moderator
 Re: Wiring 120v/240v Elec Water heater in reply to Jim Petro, 08-25-2003 18:02:03  
Some of the advice posted is just not correct. First, you need more information. The literature with the heater may have that information. Electric water heaters with elements of 5500 watts and less are properly wired with #10 wire and 30 amp breaker. If the manufacturer of the heater has a UL listing on the unit showing something different for the wiring, then the manufacturers instructions can be followed. The 6000 watt element draws 25 amperes. The assumed "continuous" load of a water heater limits the "continuous" draw on a 30 amp circuit to 80% (24 amps)-unless the manufacturer lists otherwise. The element itself should have the wattage printed on it in reasonably readable position. Get that information. Leave the factory setting for the thermostats- there is one for each element. If not to your liking after the heater is in operation, change as desired. Set both to the same temperature.

[Log in to Reply]  [No Email]
Bill 52 8n

08-26-2003 09:08:22




Report to Moderator
 Re: Re: Wiring 120v/240v Elec Water heater in reply to Bus Driver, 08-26-2003 05:02:29  
I agree with Bus Driver, my numbers came out the same as his.

Bill



[Log in to Reply]  [No Email]
Trevor

08-26-2003 15:48:26




Report to Moderator
 Re: Re: Re: Wiring 120v/240v Elec Water heater in reply to Bill 52 8n, 08-26-2003 09:08:22  
I agree with Busdriver too. These other guys are SCARY!!!

Do as Busdriver says or call a reputable electrician in your area. (hopefully not one of the guys below!!)



[Log in to Reply]  [No Email]
John Humphrey Morocco IN.

08-25-2003 19:17:32




Report to Moderator
 Re: Wiring 120v/240v Elec Water heater in reply to Jim Petro, 08-25-2003 18:02:03  
The wattage of two heaters added together is 10,500 watts, divided by 240 volts=43.75 amps. This will require a 50 amp two pole breaker and 2 conductor #8 wire along with a #12 ground. I am an electrican. Remember, bad plumbing does not burn houses down and kill our children, but poor wiring does. DO IT CORRECTLY or please get some who knows how.



[Log in to Reply]  [No Email]
Heed your own advice

08-25-2003 21:32:18




Report to Moderator
 Re: Re: Wiring 120v/240v Elec Water heater in reply to John Humphrey Morocco IN., 08-25-2003 19:17:32  
Wow... I hope you follow your own advice about (..... or please get some who knows how).
Most water heaters are wired so only ONE element can operate at a time.



[Log in to Reply]  [No Email]
etshobby

08-25-2003 19:59:18




Report to Moderator
 Re: Re: Wiring 120v/240v Elec Water heater in reply to John Humphrey Morocco IN., 08-25-2003 19:17:32  
I agree with you john the wire size should be 8-2 with ground some newer codes here call for 8/3 with ground especially in trailers . I like to set the two thermosats at least five to 10 degrees difference . The bottom element set lower then the upper seeing that heat rises to the top of the heater where it will be warmer and cold water comes in also to the bottom sometimes you only need a boost if you use a lot of water the top element will come on anyway. Oh those years add up 35 plus plumbing electrical.

[Log in to Reply]  [No Email]
buickanddeere, bottom hot

08-25-2003 21:41:36




Report to Moderator
 Re: Re: Re: Wiring 120v/240v Elec Water heater in reply to etshobby, 08-25-2003 19:59:18  
Bottom elementis to be set 10F hotter than the top. That way convection heats the entire tank when thee is no demand. If the top thermostat is set hotter, the bottom 2/3 of the tank never really warms up.



[Log in to Reply]  [No Email]
steveormary

08-25-2003 19:57:44




Report to Moderator
 Re: Re: Wiring 120v/240v Elec Water heater in reply to John Humphrey Morocco IN., 08-25-2003 19:17:32  
John,isnt the electric WH set up so only one element is on at a time. This would mean figuring the elect load at 22 amp and wire and breaker size from that. 10-2 w gr. and a 30 amp 2 pole breaker.

Jim,you right to ask. If you are not sure contact a local licensed electrician and have him do the work for you.

steve



[Log in to Reply]  [No Email]
paul

08-26-2003 22:02:57




Report to Moderator
 Re: Re: Re: Wiring 120v/240v Elec Water heater in reply to steveormary, 08-25-2003 19:57:44  
I'm a simple dirt farmer, but I had my electrical coop install an 80 gallon lifetime water heater for $120 - they can cntrol it to shave peak demands. Had a licenced plumber/electrician install it & had it inspected.

The exsisting 12 g wire was acceptable to all, as were the 15 amp fuses. It was especially discussed & looked at. My whole farm is wired from a 60 amp box - sure glad I didn't run into something needing a 50 amp breaker!!!!! The point of the big tank is that the heater is turned off from 7:00am to 11:00pm most days, & we work with stored heat. How fast do you need to heat water to need a 50 amp service to a water heater???

--->Paul

[Log in to Reply]  [No Email]
Burlgoat

08-25-2003 18:35:08




Report to Moderator
 Re: Wiring 120v/240v Elec Water heater in reply to Jim Petro, 08-25-2003 18:02:03  
Jim the wireing is basiclly the same.You will need a double pole 40 amp. breaker but you will need to run 10/2wire with aground.BTW you had a good w/h installed.Good luck with your small project.



[Log in to Reply]  [No Email]
Dusty

08-25-2003 19:09:09




Report to Moderator
 Re: Re: Wiring 120v/240v Elec Water heater in reply to Burlgoat, 08-25-2003 18:35:08  
Tell me where in the National Electial Code is sayes you can fuse #10 at 40amps for a water heater.



[Log in to Reply]  [No Email]
Slowpoke

08-25-2003 23:48:26




Report to Moderator
 Re: Re: Re: Wiring 120v/240v Elec Water heater in reply to Dusty, 08-25-2003 19:09:09  
Jim... If the plumber sold you an installed water heater, he should have left the installation manual if he expects you to wire it. The manual should include the electric hook up.



[Log in to Reply]  [No Email]
steveormary

08-27-2003 03:39:59




Report to Moderator
 Re: Re: Re: Re: Wiring 120v/240v Elec Water heater in reply to Slowpoke, 08-25-2003 23:48:26  
Jim,there should be nameplate data somewhere on the water heater. That will tell you the maximum load for the water heater. Your wire size and breaker are figured from that. You also may be required to have a safety switch close to the water heater if the water heater is not close to the electric panel.

Do you have to have a permit and have the work inspected?



[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy