BigBad88D mentioned hydra-electric, which piqued my curiosity. My neighbor had an 1800 with hydra-electric, the first one I had ever seen. How much longer did Oliver offer it, and why did they quit?




[Log in to Reply]   [No Email]
B A Star

09-05-2005 22:51:19




Report to Moderator
 Re: hydra-electric in reply to hardscrabble, 09-04-2005 18:56:03  
Harry has it about covered. The line that he speaks of is attached to the under side of the cover. Each of the valves have a spring loaded detent piston with a stem that moved into the detent groves of the valve to hold it in "work" position. When the cylinder reached the end of it's storke, either fully extended or the limit valve closed, pressure would build back to the relief valve. As pressue built, the releif valve would open and oil flow into the exhaust tube that had the restrictor cap on the bottom end. There is a drilled passage in the base housing that is in the exhaust for the relief valve that the backup pressure moved through to the cover. through a "o-ring" into the line under the cover to the detent piston to overcome the spring under the detent piston, thus moving it out of the detent grove in the valve. We had some problems with the "o-ring" between the base housing and cover. We also took the detent piston out and ground them off and installed a 1/4" ball. This allowed the operator to manually mover the vale back to "N" when he wanted to use it on a loader for example.

[Log in to Reply]  [No Email]
Dean Barker

09-05-2005 20:17:40




Report to Moderator
 Re: hydra-electric in reply to hardscrabble, 09-04-2005 18:56:03  
I have a 1973 1655 with the detent system, 3ph and 2 remotes, with the round levers. I have another 1973 1655 that had the hydra electric system with 3ph and 2 remotes. The remotes would feed each other somehow, so I traded for a detent system cover to convert it to a detent system. I understand some of the factory detent systems came with the big square levers instead of the round levers.



[Log in to Reply]  [No Email]
oliver fan

09-05-2005 08:16:23




Report to Moderator
 Re: hydra-electric in reply to hardscrabble, 09-04-2005 18:56:03  
The Oliver Hydra-lectric was available on all the 50 series and the 1555-1655 tractors. This was called a open-center hydraulic system.

In 1970 when Oliver brought out the 1755-1855-1955 tractors, they also changed the Hydraulic system. These new tractors had what was called a closed-center system. The company did not incorperate the Hydra-lectric into the new system.



[Log in to Reply]  [No Email]
J. Schwiebert

09-05-2005 09:36:06




Report to Moderator
 Re: hydra-electric in reply to oliver fan, 09-05-2005 08:16:23  
O. K. When the top cover changed on the later 50 series and the detent system was used on the rowcrop units was the hydra-lectric still available. When that pressure detent system came about there were other changes, handles being the easiest one to see. None of the later 50 series we had in stock or picked up at other dealers had top covers that would take a hydra-lectric. I am not talking depth stop units as used on industrial or wheatland tractors either.

[Log in to Reply]  [No Email]
oliver fan

09-05-2005 17:49:22




Report to Moderator
 Re: hydra-electric in reply to J. Schwiebert, 09-05-2005 09:36:06  
John, To answer your question, "Was the Hydra-lectric still available?". The answer is yes, as I stated in my orginal answer.

The question was NOT asked if any other type of hydrolic was available, and the answer would be yes, also.

Oliver had three types of hydrolics available for the Charles City built 50 series tractors.

#1 was the Hydra-lectric (3 point & 2 remote valves).

#2 was a Depth-stop unit (3 point & 2 remote valves). This is what you are describing.

#3 was a Depth-stop unit for remote cylinders only. A tractor could have 2 valves and 1 or 2 more could be added. This was more common on a wheatland or industrial tractor.

I do not know when the different versions were first introduced, but I would guess in late 1966 or early 1967.

I hope this will put any confusion to rest, unless anyone has anything to add.

[Log in to Reply]  [No Email]
J. Schwiebert

09-05-2005 18:27:10




Report to Moderator
 Re: hydra-electric in reply to oliver fan, 09-05-2005 17:49:22  
O. K. Describe the depth stop unit with the three point. Now I know my memory is not the sharpest tonight too tired I guess but the hydralectic units all had the valves for remotes and the 3 point in a series circuit. When the round handle units and the hydraulic units that had the drilled passages for releasing the depth stop came out was it the standard unit? In those the units were hooked in parallel. It just dawned on me why but getting back to the original question. When we sold a tractor to someone after this style was introduced introduced we sold no more hydralectirc units. And some of these tractor went to customers that had 3 or 4 tractors with hydra-lectric. Do you have a complete tool price book. What were the numbers for the options and how much difference in money was there. We had some (handfull) of the third system around too. I think those were Cessna built valves, never had one off the tractor.

[Log in to Reply]  [No Email]
Harry D.

09-05-2005 18:55:21




Report to Moderator
 Re: hydra-electric in reply to J. Schwiebert, 09-05-2005 18:27:10  
If I remember correctly the the lower [main] casting were similar on depth stop and hydralectric systems, the top cover and the levers changed. 1967 sounds about right for the first depth stop units. Something sticks in my mind that that the detent release pressure was transmitted to the top cover through an external line from the relief valve area, but my memory is foggy. Remotes had to be in series on open center system. Wheatland used other style valves.
Harry

[Log in to Reply]  [No Email]
hardscrabble

09-05-2005 19:17:09




Report to Moderator
 Re: hydra-electric in reply to Harry D., 09-05-2005 18:55:21  
Perhaps I should clarify. My neighbor's 1800 was a Wheatland. It had no 3-point. The lever for the valve had a pushbutton at the top. There was an elctrical outlet attached to the bracket for for the remote couplers, and an electrical cord was attached to one of the hoses on the hydraulic cylinder. The cord end and mating outlet were similar to a 5 or 6 pin trailer hookup.



[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy