05-09-2008 08:58:34




Report to Moderator

Here"s the detail, any help would be appreciated.

The tractor is a 1954 model 60, 12 volt with alternator, negative ground and automatic fuel shutoff. New intake and exhaust manifold, heat exchanger, coil, plugs, wires, guages, batteries, rebuilt starter and rebuilt dltx81 carb. Throttle linkage is adjusted per manual and she idles good at about 550 - 600 rpms. Batteries have been load tested and are good, alternator has been tested and is good. She starts real easy with no smoke and will idle good or pull anything for about 20 minutes then she just shuts down. I"ve replaced the carb float and checked for proper fuel level (3/8" from top of bowl). The sediment bowl and diaphram on the fuel shut off have been replaced and I"ve looked them over again since, the diaphram looks fine. Why won"t it run more than about 20 minutes? If I wait about 6 hours she will restart and run again...for about 20 minutes.

Thanks
Clint

[Log in to Reply]   [No Email]
Larry in WNY

05-09-2008 18:04:01




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to cwjohn, 05-09-2008 08:58:34  
Clint,

Looking in my parts book for JD 60 tractors for S/N 6026000-6029999, one wire goes from the coil to a resistor. The other coil wire goes to the distributor. I don"t see a ballast resistor on here like with a 620. That tells me something has to reduce the voltage to 6 volts since it"s suppose to have a 6 volt coil and 12 volts will burn up the points. The resistor may be on the switch. On our JD 620, the ballast resistor is separate from the switch. The 620 wouldn"t run after this resistor got really hot. So maybe your problem is with the resistor on your ignition/light switch. Just a thought and I don"t claim to be a good electrician. I did replace my JD 60s switch when I had problems and it still runs good today.

Larry

[Log in to Reply]  [No Email]
Rich Duane

05-09-2008 16:48:45




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to cwjohn, 05-09-2008 08:58:34  
I didn't see anyone mention a negitive ground coil being you changed to an alternator.

Rich Duane



[Log in to Reply]  [No Email]
Tom 43

05-09-2008 16:23:57




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to cwjohn, 05-09-2008 08:58:34  
Dear Clint,
When the tractor stops after 20 minutes, do you have spark? Spark should jump almost a quarter of an inch from plug wire to ground and be a nice fat spark that you can hear. Check the fuel level in the carburetor when it won't start. The bowl should be full. The first numbered series didn't have a resistor unless LP. With the points closed you should have 12 volts on the battery side of the coil and 0 volts on the distributor side of the coil.

[Log in to Reply]  [No Email]
55 50 Ron

05-10-2008 13:16:39




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to Tom 43, 05-09-2008 16:23:57  
My first numbered series (model 50) is not an LP and it does have the ignition resistor. Also the parts book shows it is supposed to have the resistor. If any of these tractors doesn"t have the resistor it means they have had the coil changed to a true 12 volt coil.



[Log in to Reply]  [No Email]
johns48jdb

05-09-2008 15:32:29




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to cwjohn, 05-09-2008 08:58:34  
i had a 45 jd combine that would shut down when the coil got hot. replaced it and no more problems.



[Log in to Reply]  [No Email]
cwjohn

05-09-2008 10:15:37




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to cwjohn, 05-09-2008 08:58:34  
Thanks for all the ideas. I forgot to mention that the points and condenser are new as well as dustcap, rotor and distributor cap.

Gas tank is has the vent tube and non vented cap with new cork gasket. Fuel lines are metal, oil pressure is good to the end, right in the middle, ammeter show about 12 volts to the end.

I do have the resistor switch, I'll have to check the wiring on it. Coil doesn't feel hot after it dies, always thought that heat meant it was bad. Plunger and gasket on fuel strainer move properly.

[Log in to Reply]  [No Email]
Mike M

05-09-2008 10:29:30




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to cwjohn, 05-09-2008 10:15:37  
Alot of good ideas here. I especially like FITs idea of using the timing light so you can see if it is sparking as it is dying. With that said and all those NEW parts replaced. NEW parts CAN be bad. I have had on 2 occasions new condensors cause me grief.

The resistor on the back of the switch is for high and low beam lights. If you happen to have a bypass starting resistor it will be seperate and you will also have to have a small post on the side of your starter switch to send full 12 volts up to the coil + side upon starting then while running the voltage measured at the coil should drop back to 6 volt when the starter is released. You may not have or even need this feature. I once fixed a 620 that had this wired up wrong and was causing running problems.

[Log in to Reply]  [No Email]
cwjohn

05-10-2008 12:40:04




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to Mike M, 05-09-2008 10:29:30  
Mike, I don't have a bypass resistor and when I replaced the coil I picked up a 12 volt coil. I'm sending 12 volts from the battery thru the switch to the coil and on into the distributor. Should the distributor only be getting 6v and thats burning up my condenser?



[Log in to Reply]  [No Email]
F-I-T

05-09-2008 10:54:05




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to Mike M, 05-09-2008 10:29:30  
Mike:

I have an old neon, self-powered timing light from way back when. That dog gone thing has saved me more grief, especially on small engines where you just never know if you are getting good spark. On an engine or tractor that is suspect, I just tape it fast with some duct tape, like right in front of me on the hood while I go driving, and when she dies, it just takes a glance up to see if it's sparking during the "event".

[Log in to Reply]  [No Email]
cwjohn

05-09-2008 10:41:26




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to Mike M, 05-09-2008 10:29:30  
I just looked at the starter switch. The only thing hooked to the resistor is the lights.

The battery has a large gauge wire directly to the starter. The battery also has an 8 ga wire to the ammeter and to the center post of the switch, looks like it is labled "bat".

The coil is connected to the top post on the switch labled 'ing'.

The Alternator wire goes to the side of the ammeter opposite the battery wire. This is it for wiring. Anyone see a problem there?

[Log in to Reply]  [No Email]
Mike M

05-09-2008 12:35:09




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to cwjohn, 05-09-2008 10:41:26  
I don't see a problem so far ? I am wondering if you got a bum condenser.



[Log in to Reply]  [No Email]
cwjohn

05-10-2008 12:27:58




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to Mike M, 05-09-2008 12:35:09  
And the winner is... Bad condenser. Changed it out and got my disking finished. Thanks for all the help!



[Log in to Reply]  [No Email]
Mike M

05-10-2008 13:10:13




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to cwjohn, 05-10-2008 12:27:58  
And Thanks for posting the cure !



[Log in to Reply]  [No Email]
55 50 Ron

05-09-2008 13:14:08




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to Mike M, 05-09-2008 12:35:09  
Delco condensor number 12338664 is recommended for these tractors. (It is also known as a D203)

One other thing. Is the ignition/light switch new? I recently had a situation where the tractor would start fine and stop after releasing the starter pedal. The ignition/light switch was intermitent on the ignition position. That position is bypassed for starting if you have the bypass system resistor, but as others have said not all of these tractors have that bypass. Even if it had the bypass from the factory, some folks remove it and change coils to accommodate for the bypass removal.

I find that 20 mins on a JD 2 cyl is enough of a "daily fix" but I well realize that doesn't work for others. :) :) :)

[Log in to Reply]  [No Email]
Mike M

05-09-2008 16:35:16




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to 55 50 Ron, 05-09-2008 13:14:08  
Don't bother trying to find the Delco ones as I did a few years back. Inside the box they were the same Mexico ones you can get at auto zone or TSC or Deere. The points and cond. are the same as some old Delco equipped cars and trucks I got some cheap at Auto Zone once.



[Log in to Reply]  [No Email]
cwjohn

05-09-2008 10:43:02




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to cwjohn, 05-09-2008 10:41:26  
Also, I blew out the vent tube on the gas tank before I installed it and after she dies there is no 'woosh' like she is sucking in air.



[Log in to Reply]  [No Email]
Rodney Hecksel

05-09-2008 09:16:29




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to cwjohn, 05-09-2008 08:58:34  
ANOTHER THOUGHT IS A BAD COIL.



[Log in to Reply]  [No Email]
F-I-T

05-09-2008 09:10:10




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to cwjohn, 05-09-2008 08:58:34  
Do you have the proper fuel cap on the '60'? I would take the fuel cap off and try to run it. If it goes longer than 20 minutes, you probably have a venting issue. Either wrong cap, or a tank vent tube that is obstructed. I think the '60' used a vented cap on the early models, then they went to an unvented cap and separate vent line on later models.

But as always, you need to hook a timing light to it so that you know that when it quits it still had spark.

[Log in to Reply]  [No Email]
Rodney Hecksel

05-09-2008 09:09:46




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to cwjohn, 05-09-2008 08:58:34  
ONLY IDEAS I HAVE ARE:
SOMETHING BLOCKING FUEL FLOW INSIDE OF THE GAS TANK. OR A RUBBER HOSE FUEL LINE THAT IS COLLAPSING AFTER GETTING WARM. OR EVEN POSSIBLE VAPOR LOCKING.(DO YOU HAVE ORIGINAL FUEL LINES AND ROUTING OF LINES? IF LINE GETS TOO HOT IT WILL VAPOR LOCK.) DO YOU HAVE GOOD OIL PRESSURE AFTER TRACTOR RUNS FOR THE 20 MINUTES? IF PREESURE GOES TOO LOW, THE AUTOMATIC FUEL SHUT-OFF WILL TRIP. JUST THROWING OUT SOME IDEAS.

[Log in to Reply]  [No Email]
Mike M

05-09-2008 09:07:43




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to cwjohn, 05-09-2008 08:58:34  
In your list of new or rebuilt parts I saw no mention of points and condenser. I would start there. Plus make sure since neg. ground the coil is hooked up for neg. ground. the - will then go to the wire that goes to the dist. Not sure if that year 60 used the bypass starting resistor yet or not. If you have one it may not be wire up right ? Also look into the glass fuel bowl and make sure when the center plunger goes down the little rubber washer goes down with it because if it sticks to the top it will restrict the flow.

[Log in to Reply]  [No Email]
dr mike lokai

05-09-2008 13:42:48




Report to Moderator
 Re: 60 won't run more than about 20 minutes in reply to Mike M, 05-09-2008 09:07:43  
CHECK YOUR TANK FOR SEDIMENT,USE A PEN LIGHT TO VISUALIZE THE BOTTOM.YOU WILL BE SURPRISED WHAT 50 YEARS OF USE WILL LEAVE BEHIND.SEDIMENT FROM THE TANK WALL IS COMMON PLACE.1.HAVE A REDIATOR SHOP CLEAN AND RELINE THE TANK OR 2.USE A LONGER INLET STEM ON THE SEDIMENT BULB (AVAILABLE AT JOHN DEERE) AND INCLUDE A INLINE FILTER TO TRAP SEDIMENT.GET RID OF THE DIAPHRAM SEDIMENT BULB.



[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy