08-14-2007 06:22:02




Report to Moderator

I was plowing a six acre field this past weekend and was about 3/4 done when the tractor just quit. The engine never sputtered or faultered in any way. I first thought I might be out of gas (gauge hasn't worked in about a year), but I actually had about 1/3 tank. I had plenty of juice in the battery, the starter motor fired and the engine turned over well. I had good gas flow, but when I checked for spark I had none at either plug. My first thought was the coil failed. I know sometimes if the coil is on the verge of going out, it can inhibit spark when the engine gets hot under load. I let the tractor cool down for a few hours to ambient temperature and attempted to restart. It fired right up, but I decided to not run it long or work the tractor at that point. By now I was pretty sure the coil was the problem. I believe the existing coil may still have been original. At least I never needed to replace it in the 15 years I have owned the tractor. I replaced the coil with a new one on Monday evening. The engine fired right up and I began to plow again. Plowed for about an hour and the engine just quit, same as before. Let things cool down and attempted to restart. This time the engine would not restart. No spark again. Water temperature never got above 220 under load, normal is about 200. Do you think I toasted the new coil? What else may be the problem? Where do I look now? Any advice or help is greatly appreciated. Thanks.
Rick

[Log in to Reply]   [No Email]
Rick Kaufmann

08-15-2007 05:36:32




Report to Moderator
 Re: Help! 530 Ignition Problems in reply to Rick Kaufmann, 08-14-2007 06:22:02  
I replaced points and condensor and am back up running again, but with my fingers crossed. I will look into the ballast resistor and relace that asap to avoid premature problems with the new coil, points, and condensor. Thanks again guys for all your help.
Rick



[Log in to Reply]  [No Email]
Mike M

08-15-2007 07:49:13




Report to Moderator
 Re: Help! 530 Ignition Problems in reply to Rick Kaufmann, 08-15-2007 05:36:32  
While your at it clean and check all your wires and connections too.



[Log in to Reply]  [No Email]
Rick Kaufmann

08-14-2007 10:05:52




Report to Moderator
 Re: Help! 530 Ignition Problems in reply to Rick Kaufmann, 08-14-2007 06:22:02  
55-50: As far as coolant temperature, I don't think that 220 was inordinately high considering the conditions. 90 plus degrees in full sun and pulling 3-14's in heavy sod. Temp gage goes to 230, never pegged it. I previously bush hogged 8 acres of high grass/weeds twice this summer with a six foot cut and never saw the temp go above 210. I replaced one of the battery cables a few years ago (can't remember which one, think the positive cable)and rewired the entire tractor 10-12 years ago not long after I bought it.
Rick

[Log in to Reply]  [No Email]
Rick Kaufmann

08-14-2007 09:50:09




Report to Moderator
 Re: Help! 530 Ignition Problems in reply to Rick Kaufmann, 08-14-2007 06:22:02  
Yes, the new coil is a 6-volt also. I never heard of an external ballast resistor nor do I know what one looks like. Where would I find it? The local JD dealer has a set of points and condensor in stock which I will pick up this afternoon. As I said earlier, the points are not that old, and looked pretty decent (no serious pitting or carbon build-up), but it sure won't hurt to change them out along with the condensor. Thanks again to all for your replies and good advice.
Rick

[Log in to Reply]  [No Email]
55 50

08-14-2007 23:12:55




Report to Moderator
 Re: Help! 530 Ignition Problems in reply to Rick Kaufmann, 08-14-2007 09:50:09  
The battery is 12 volts I assume. So if the coil is a 6 volt, that means for sure you need the ballast resistor. If the ballast resistor is bad, you will overheat the coil and cause points, condensor and coil to fail prematurely.
A suitable resistor can be purchased at an auto parts store if your JD dealer doesn't have it.



[Log in to Reply]  [No Email]
Mike M

08-14-2007 12:50:39




Report to Moderator
 Re: Help! 530 Ignition Problems in reply to Rick Kaufmann, 08-14-2007 09:50:09  
I'm thinking the resistor on those is behind the dash panel.



[Log in to Reply]  [No Email]
55 50

08-14-2007 09:37:36




Report to Moderator
 Re: Help! 530 Ignition Problems in reply to Rick Kaufmann, 08-14-2007 06:22:02  
Coolant temperature at 220 seems high to me. Are you worried about that?



[Log in to Reply]  [No Email]
John T

08-14-2007 08:51:43




Report to Moderator
 Re: Help! 530 Ignition Problems in reply to Rick Kaufmann, 08-14-2007 06:22:02  
Rick, The "Usual Suspects" for ignition failure after warm up are indeed the coil as you suspected and the condensor as Mike told ya or else the points may be burned n carboned and heat increases the resistance. Since you already got the coil, a new set of points n condensor is also my next best bet along with the other fine gents. Was your old coil a 6 volt?? and is your new coil the same??? I ask cuz that tractor may have (cant ever tell if it was modified over the years) a 6 volt coil plus the external ballast resistor WHICH IS ONE MORE THING THAT COULD GO BAD AFTER WARMED UP !!!!! !!

Condensor like Mike told ya,,,Points,,,,Ballast Resistor is where Id look next.

Pertronix has an elec ignition module for that tractor, about the only external visible difference (if the Correct Police concern you) is there are 2 instead of only one wire coming from the distributor to the coil but a good job of wiring and a loom/cover can hide that lol. I higly recommend to get the most bang for the buck an elec ignition has to offer is to match it up with a high energy high voltage coil and run a wider plug gap wooooo hooooo ooo

John T

[Log in to Reply]  [No Email]
55 50

08-14-2007 09:44:06




Report to Moderator
 Re: Help! 530 Ignition Problems in reply to John T, 08-14-2007 08:51:43  
John,

Sometime you should put on here a sound bite of that "wooooo hooooo" !!!!! (did I include enough oooos?) Ron



[Log in to Reply]  [No Email]
Rick Kaufmann

08-14-2007 08:16:29




Report to Moderator
 Re: Help! 530 Ignition Problems in reply to Rick Kaufmann, 08-14-2007 06:22:02  
Thanks Mike M. and Machinery-Man. I'll try a new condenser this evening for now. Current condensor and points are not new but don't have that many hours on them. Wires same as the points/condensor. Plugs are brand new. Generator rebuilt about a year ago along with a new voltage regulator. Machinery-Man, I would be interested in the electronic ignition but never heard of it for two cylinder JD's. Where do you get them and how much do they cost? Eventually I would like to upgrade to a newer tractor in the 50-80 HP range,JD for sure, and restore the 530 since they have decent value these days. Are there any implications in terms of decreasing/increasing market value of the machine if I do convert to electric ignition? Thanks again and keep the advice coming if anyone out there has more to offer.
Rick

[Log in to Reply]  [No Email]
55 50

08-14-2007 09:41:16




Report to Moderator
 Re: Help! 530 Ignition Problems in reply to Rick Kaufmann, 08-14-2007 08:16:29  
You mentioned wires don't have that many hours on them. Does that mean all the wires all the way from the battery to the coil? I've seen some wires in the area of the battery on the old JDs that were questionable.



[Log in to Reply]  [No Email]
machinery-man

08-14-2007 08:45:47




Report to Moderator
 Re: Help! 530 Ignition Problems in reply to Rick Kaufmann, 08-14-2007 08:16:29  
my kits came from Genessee Electronics but they are Petronix...same as used in automotive but the donut(ring that goes over shaft is for 2 cylinder. There's no comparison as to performance...about 35,000 volts output...I ran a garden hose over the distributor and it fired, even fluided the tractor with the black stuff blowing out exhaust and plugs fired and cleared up...try that with regular ignition...choice of plugs didn't matter..even used some old plugs...the man I spoke to was Andy and they have a web site...

[Log in to Reply]  [No Email]
machinery-man

08-14-2007 07:30:25




Report to Moderator
 Re: Help! 530 Ignition Problems in reply to Rick Kaufmann, 08-14-2007 06:22:02  
I went to the electronic ignition with fantastic results...hi output coil, eliminates the bouncy points and condensor failures. Smoother engine performance and better burning of fuel. About the heat, I imagine when you are flat out pulling, plowing the temp gauge will probably peg, did so on my tractors...guess it depends on how hard you"re pulling to some degree and blend of coolant mixture. Can"t say it hurts anything as all the older tractors seem to hit the high point...

[Log in to Reply]  [No Email]
Mike M

08-14-2007 06:28:00




Report to Moderator
 Re: Help! 530 Ignition Problems in reply to Rick Kaufmann, 08-14-2007 06:22:02  
Try a condenser.



[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.