Roger in Iowa

11-15-2006 18:04:53




Report to Moderator

Paul, about 3 pages down needs some help with 2630 and log splitter. I have about ran out of ideas!

Roger in Iowa




[Log in to Reply]   [No Email]
Paul Szikszai

12-18-2006 14:40:35




Report to Moderator
 Re: 2630 and log splitter in reply to Roger in Iowa, 11-15-2006 18:04:53  
Roger and everyone else that helped, THANKS.

I picked up my Breakaway coupler from JD this weekend.
They said there was nothing wrong with them.
The only other thing they said was that one outlet of the coupler is the power coupler and the other is for return.
Based on this information I replummed the valve on the splitter.
When I tried it The cylinder on the splitter would move about two inches than stop
I reset the remote cylinder operating lever and tried it again, same result.
Then I stuck a piece a wood into the remote cylinder lever to stop it from resetting.
Everything worked fine.

Later I read in one of my manuals that JD sells a leverlock for continous operation.

Once again thanks everyone.
Paul

[Log in to Reply]  [No Email]
Roger in Iowa

11-18-2006 08:43:58




Report to Moderator
 Re: 2630 and log splitter in reply to Roger in Iowa, 11-15-2006 18:04:53  
Paul, do you have a 3 point hitch on this tractor?
Are you using the control for it to run the splitter? Can you post a picture of the valve and coupler area?

Roger in Iowa



[Log in to Reply]  [No Email]
Paul Szikszai

11-17-2006 09:56:22




Report to Moderator
 Re: 2630 and log splitter in reply to Roger in Iowa, 11-15-2006 18:04:53  
Per Roger's suggestion I ceased using the valve on the splitter.
Hooked up the two hoses directly to the splitter's cylinder.
The cylinder now goes forward but does not return.
I took off the Breakaway Coupler in preparation to
take it to the JD dealer to have it checked out.
It then occured to me to see if I can blow air though the two receptacles. I inserted the two male plugs and tried it. I could not blow air through either one.
I then turned the two Coupler Operating Levers to the right angle to the hoses as supposed to. Then I could blow air thru the receptacles though the male couplers, also from the 90% elbows at the back of the breakaway coupler, (both of them).
I don't know if this proves anything, if so is there a reason for me to take the Breakaway Coupler to the JD dealer?
Thanks Paul.

[Log in to Reply]  [No Email]
low budget

11-17-2006 11:57:47




Report to Moderator
 Re: 2630 and log splitter in reply to Paul Szikszai, 11-17-2006 09:56:22  
I did once buy a new male coupler tip that was defective and restrict flow, but it's really starting to to sound like a malfunctioning selective control valve on the tractor.(Broken or worn parts or debris, the valves are rebuildable, but its a job for the dealer due to very precise adjustments.) You could always buy one more new tip and try swapping with each of the ones you have to eliminate the possibility of it being the tip. (they may behave differently with oil instead of air.) To test your tractor control valve rig up a male coupler on a pressure guage (3000 lb min.) Try it on one female break away coupler at a time. Moving the tractor lever one way will build pressure, nuetral position will hold pressure, and moving the lever the opposite way pressure should drop immediately. Each side will work opposite of the other. I have a feeling you will find one side is not releasing pressure or releasing very slowly.If you have anymore questions you can email me.

[Log in to Reply]  [No Email]
Dave in Tx

11-16-2006 16:50:41




Report to Moderator
 Re: 2630 and log splitter in reply to Roger in Iowa, 11-15-2006 18:04:53  
My experience with the same thing he is doing, is he is running the oil thru the splitter valve the wrong way. open center valve will work good , just have to have oil going thru valve the right way, pressure line to input side of valve. Have done it many times on both open and closed systems



[Log in to Reply]  [No Email]
Dave Sherburne NY

11-16-2006 10:25:47




Report to Moderator
 Re: 2630 and log splitter in reply to Roger in Iowa, 11-15-2006 18:04:53  
I just looked at the JD parts site, On the bottom of the breakaway coupler there are two levers which after inserting the hose ends must be turned 90 degrees to let the oil flow thru. If one is not turned, the hose will pop out when presure is applied. As far as the float position on the valve is concerned, thats not hard to tell, because it has a detent in the float position. I think perhaps he hasn't turned the levers, or else one of his hose ends is wrong and is not being opened by turning the levers. Of couse, there is another breakaway coupler that doesn't have the levers on the bottom .I had a 26 40 til last year, but its 10 miles away now and I can't check it.

[Log in to Reply]  [No Email]
mjbrown

11-16-2006 03:55:48




Report to Moderator
 Re: 2630 and log splitter in reply to Roger in Iowa, 11-15-2006 18:04:53  
Did he get new hoses and ends ?
He has too many valves I think and the one on the splitter is not compatable with the tractor. He should use the tractor valve to run the splitter and make an extension for the valve handle.
I assume he has the little lever under the scv body turned to open the remote ends.



[Log in to Reply]  [No Email]
msb

11-15-2006 21:09:21




Report to Moderator
 Re: 2630 and log splitter in reply to Roger in Iowa, 11-15-2006 18:04:53  
An open center system will only build what pressure the function calls for,typically 1500 PSI or less.On a splitter probably only a few hundred pounds would split any hardwood.

A 2630 will build about 2250 PSI stand by pressure regardless of the need to operate the function.So the blown hose was probably never exposed to that much pressure on a wood splitter and was either defective or not to be used under that much pressure.Regardless the hose if in good condition should not have blown if it was the proper pressure rating for your tractor.Sorry, I don't remember who said the valve needs the return plug changed to one for a closed center system, but that is correct.If the valve is hooked to the scv valve on the tractor then the scv valve will have to be wired or otherwise held in operating position so the splitter valve will always be getting a supply of pressure oil.
If the return oil is dumped back through the SCV valve then that might possibly slow the cylinder down a bit , but it should also never blow a hose.Not to say the hose may not pop out of the breakaway coupler on occasion, but it should not rupture the hose itself if that is what happened to the old hose.

[Log in to Reply]  [No Email]
CPeter

11-15-2006 19:14:05




Report to Moderator
 Re: 2630 and log splitter in reply to Roger in Iowa, 11-15-2006 18:04:53  
Closed center machines are not my area of expertise, but here goes. I think you need to 1st get a closed center control valve for you splitter. Then Tee into the two lines that feed and return on you loader control valve. Then the two valves will operate in parallel. The other choice is to get a selection valve and cut that into the lines that go to the bucket cylinders on the loader from the bucket control valve. The first option is the cheapest. Cut in the tee, install the quick disconnect and you are off and running.

CPeter

[Log in to Reply]  [No Email]
Bob

11-15-2006 19:13:23




Report to Moderator
 Re: 2630 and log splitter in reply to Roger in Iowa, 11-15-2006 18:04:53  
It sounds to me like one of the male hydraulic coupler tips is either defective, ot does not match up with the coupler barrel in the tractor.



[Log in to Reply]  [No Email]
CPeter

11-15-2006 19:16:02




Report to Moderator
 Re: 2630 and log splitter in reply to Bob, 11-15-2006 19:13:23  
That is a possibility, but how does the oil get out of the other sice of the piston? It might be acting like a check valve and only allow the oil to go in one direction??

CPeter



[Log in to Reply]  [No Email]
MSM

11-16-2006 07:13:38




Report to Moderator
 Re: 2630 and log splitter in reply to CPeter, 11-15-2006 19:16:02  
The oil returns through the splitter valve then back into the tractor.
You need a closed center valve on the splitter,the tractor control lever will have to be tied to the rear,make sure you have the correct hose ends,the ones that fit the ford are not compatable with the John Deere,unless you use a set of adapters.Make sure the hose that feeds the splitter valve is connected to the pressure side of the remote. As was stated in the post above,make sure once the hoses are plugged ito the remote on the tractor,you turn the levers under the coupler to the side to open them.

[Log in to Reply]  [No Email]
Paul Szikszai

11-17-2006 10:00:49




Report to Moderator
 Re: 2630 and log splitter in reply to MSM, 11-16-2006 07:13:38  

Per Roger's suggestion I ceased using the valve on the splitter.
Hooked up the two hoses directly to the splitter's cylinder.
The cylinder now goes forward but does not return.
I took off the Breakaway Coupler in preparation to
take it to the JD dealer to have it checked out.
It then occured to me to see if I can blow air though the two receptacles. I inserted the two male plugs and tried it. I could not blow air through either one.
I then turned the two Coupler Operating Levers to the right angle to the hoses as supposed to. Then I could blow air thru the receptacles though the male couplers, also from the 90% elbows at the back of the breakaway coupler, (both of them).
I don't know if this proves anything, if so is there a reason for me to take the Breakaway Coupler to the JD dealer?
Thanks Paul.

[Log in to Reply]  [No Email]
Roger in Iowa

11-17-2006 15:34:30




Report to Moderator
 Re: 2630 and log splitter in reply to Paul Szikszai, 11-17-2006 10:00:49  
Paul, I think you should get a gauge and install it using one of your hoses. Check one outlet at a time.

It could still be one of the tips but could also be one of the outlets.

This is a toughie! How is your loader plumbed?

Roger in Iowa



[Log in to Reply]  [No Email]
Paul Szikszai

12-18-2006 14:47:58




Report to Moderator
 Re: 2630 and log splitter in reply to Roger in Iowa, 11-17-2006 15:34:30  
Roger and everyone else that helped, THANKS.

I picked up my Breakaway coupler from JD this weekend.
They said there was nothing wrong with them.
The only other thing they said was that one outlet of the coupler is the power coupler and the other is for return.
Based on this information I replummed the valve on the splitter.
When I tried it The cylinder on the splitter would move about two inches than stop
I reset the remote cylinder operating lever and tried it again, same result.
Then I stuck a piece a wood into the remote cylinder lever to stop it from resetting.
Everything worked fine.

Later I read in one of my manuals that JD sells a leverlock for continous operation.

Once again thanks everyone.
Paul
Duplicate message as first was entered out of sequence.

[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy