VAC hydraulic pump question

Welcome Guest, Log in or Register
Author 
Jerry W

06-01-2004 15:30:32




Report to Moderator

Does anybody know what the pressures and gpm's are for the belt pulley driven pump versus the gear pump driven out of the magneto hole on the engine?

I am setting up a loader on my VAC and need to know.

My manual did not explain this.

Thanks Jerry




[Log in to Reply]   [No Email]
BLR

06-05-2004 23:37:54




Report to Moderator
 Re: VAC hydraulic pump question in reply to Jerry W, 06-01-2004 15:30:32  
I have a VA with a loader, and my recommendation is to run the loader off of the engine driven pump through an open center valve, which will give you the option of having pressure up and down on the loader and a hydraulic bucket. All that gets fairly complicated using the pulley pump. The main problems are having enough reservior and the correct valving to make a usable loader system. I have set the pressure relief in the 4 spool open center valve on my tractor to release at 450 psi, and this provide more lift than the wieght of the tractor can support. If I pick up the heaviest load that the tractor will lift traction is a premiuim. Additonally, this prevents me form breaking something. The 4 spool valve provides for the loader, one set of dual remotes, and one open valve for something else.

[Log in to Reply]  [No Email]
mj

06-04-2004 11:19:49




Report to Moderator
 Re: VAC hydraulic pump question in reply to Jerry W, 06-01-2004 15:30:32  
Pressure-relief on belt pulley pump should bypass at 2000 psi and gpm is about 2.0 while the engine mounted pump is rated at 900 psi and 7.0 gpm....get a rear-mount PTO pump rated around 12 gpm and 2000 psi for loader/backhoe work along with an adj. relief valve if loader doesn't have one so you can match pump output to cylinder specs.

[Log in to Reply]  [No Email]
Art

06-02-2004 03:49:44




Report to Moderator
 Re: VAC hydraulic pump question in reply to Jerry W, 06-01-2004 15:30:32  
Case also manufactured a high volume hyd pump. I have one for my loader on my VAI. This goes in the same mounting hole that the other gear driven pump goes in. You have to take out the dist. in order to get it in/out. That show how much bigger it is than the regular one....They are hard to find.Good luck



[Log in to Reply]  [No Email]
Joe (Wa)

06-02-2004 08:23:27




Report to Moderator
 Re: Re: VAC hydraulic pump question in reply to Art, 06-02-2004 03:49:44  
Art, Is this the pump you are talking about? Never saw or heard of one and have been wondering.

Joe



[Log in to Reply]  [No Email]
Art

06-02-2004 09:13:22




Report to Moderator
 Re: Re: Re: VAC hydraulic pump question in reply to Joe (Wa), 06-02-2004 08:23:27  
Hey Joe....No, the pump I have on my 46 VAI is mounted in the same spot as the ones mounted on the front of the motor. It's at least twice as thick as the smaller pump that runs the eagle hitch. And it doesn't look anything like the little one.



[Log in to Reply]  [No Email]
Joe (Wa)

06-02-2004 11:42:12




Report to Moderator
 Re: Re: Re: Re: VAC hydraulic pump question in reply to Art, 06-02-2004 09:13:22  
Ok Art, your pump is live engine driven, makes more sense for loader work.

I guess that belt pulley gear drive pump on ebay must be for remotes, log splitter, PHD, etc. Wouldn't be much use on a loader.

Joe



[Log in to Reply]  [No Email]
Joe (Wa)

06-02-2004 09:01:36




Report to Moderator
 Re: Re: Re: VAC hydraulic pump question in reply to Joe (Wa), 06-02-2004 08:23:27  
Another question, are you using the torque tube as a reservoir for your pump?

Joe



[Log in to Reply]  [No Email]
Art

06-02-2004 09:16:35




Report to Moderator
 Re: Re: Re: Re: VAC hydraulic pump question in reply to Joe (Wa), 06-02-2004 09:01:36  
no the front end loader has its own reservior mounted up on the side of the frame of the loader.



[Log in to Reply]  [No Email]
GeoMo

06-02-2004 06:01:37




Report to Moderator
 Re: Re: VAC hydraulic pump question in reply to Art, 06-02-2004 03:49:44  
I have a combine pump on my VAC.
I use one stage for 3-point and one for remote.
If you go thru the archives I thank that you can find the pump/combine #.



[Log in to Reply]  [No Email]
DCTOM

06-01-2004 18:29:23




Report to Moderator
 Re: VAC hydraulic pump question in reply to Jerry W, 06-01-2004 15:30:32  
I BELEIVE THE PISTON PUMP IN THE PULLY HAS 4500# PRESSURE BUT NO GALLONS PER MINUT MAYBE A PINT, WOULD BE VERYSLOW ON A LOADER, TOM



[Log in to Reply]  [No Email]
Joe (Wa)

06-01-2004 19:17:31




Report to Moderator
 Re: Re: VAC hydraulic pump question in reply to DCTOM, 06-01-2004 18:29:23  
Working press is 4500 psi. Realistically you would lower that under 2000 psi and as far down as 1000 psi. I've never seen GPM rating or as Tom said more like PPM.

Reservoir is too small, figure the difference between piston end and rod end of the cylinders plus about 1/2 reservoir capacity. Not much chance.

Joe

Joe



[Log in to Reply]  [No Email]
mj

06-04-2004 11:22:54




Report to Moderator
 Re: Re: Re: VAC hydraulic pump question in reply to Joe (Wa), 06-01-2004 19:17:31  
Sorry Joe, but the relief valve should be set at 2000 psi....Roger?



[Log in to Reply]  [No Email]
Jerry W

06-04-2004 13:47:09




Report to Moderator
 Re: Re: Re: Re: VAC hydraulic pump question in reply to mj, 06-04-2004 11:22:54  
That is the pump that mounts under the belt pulley on the early cultivator lifts. It was not for the Eagle Hitch as it was listed. The Eagle hitch used the engine mounted gear pump.

Jerry



[Log in to Reply]  [No Email]
Joe (Wa)

06-04-2004 15:12:29




Report to Moderator
 Re: Re: Re: Re: Re: VAC hydraulic pump question in reply to Jerry W, 06-04-2004 13:47:09  
Jerry, I agree that the 1949 and later eagle hitch is run by the engine driven pump. That pump is low pressure with the specs mj mentioned. Most of all it provides live hydraulics.

The pump on ebay appears to be a piston type high pressure pump and can not provide live hydraulics running off the belt pulley gear. The seller states it will only fit late model Vac.

My question is:

What is the purpose of a non-live high pressure pump that can only be mounted on a later model Vac that already has a LP pump & eagle hitch as standard factory equipment?

I haven't a clue, just asking.

Joe

[Log in to Reply]  [No Email]
Jerry W

06-07-2004 19:46:52




Report to Moderator
 Re: Re: Re: Re: Re: Re: VAC hydraulic pump questio in reply to Joe (Wa), 06-04-2004 15:12:29  
Joe I think this guy is all wet on his facts. I'm not an expert - Just a guy who used to wrench on Case. I have never seen this pump on a 1949 or newer VAC.

I believe that this piston pump was replaced by the engine mounted gear pump. This pump - in my opinion - is neither late model nor for the Eagle hitch.

Just my opinion - Jerry



[Log in to Reply]  [No Email]
Joe (Wa)

06-04-2004 12:00:39




Report to Moderator
 Re: Re: Re: Re: VAC hydraulic pump question in reply to mj, 06-04-2004 11:22:54  
Yeah, I got the info out of an I&T service manual.
"The relief valve should unload when the pressure is within the range of 4350-4500 psi"...."varied by adding and removing shims". Probably bad info, seems more reasonable for it to be 2000 psi or less for the type of piping and hyd equip normally found on tractors.

None of my Case manuals address pressure or capacity, just the free & compressed length of the relief valve spring.

Did you see the picture that I posted of the one on ebay? What in the world is that pump for?

Joe

[Log in to Reply]  [No Email]
mj

06-08-2004 02:11:18




Report to Moderator
 Re: Re: Re: Re: Re: VAC hydraulic pump question in reply to Joe (Wa), 06-04-2004 12:00:39  
That's a high-pressure piston pump from the belt-pulley setup....I believe that Case still offered these even after the live pump setup came out , until possibly, '51 or 52 as not all farmers wanted and /or needed the new Eagle hitch.



[Log in to Reply]  [No Email]
mj

06-05-2004 15:21:47




Report to Moderator
 Re: Re: Re: Re: Re: VAC hydraulic pump question in reply to Joe (Wa), 06-04-2004 12:00:39  
I don't want to be there when someone shims one of these pumps to 4500 psi!



[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy