Posted by HWooden on September 24, 1999 at 17:26:39 from (165.117.55.23):
In Reply to: help with 12 volt conversion posted by Sam on September 24, 1999 at 12:28:52:
With the dist. points open and ignition sw. on, the meter will read batt volts (12 ). With the sw. on and points colsed meter should read 5.5- 7.5 Volts. There should not be more than (three-tenths).3 volt drop across the points when they are closed (switch on engine not running) Hope this helps.