Tractor Talk Discussion Board |
Re: loader conversion to full hydraulics
[ View Follow Ups ] [ Post Followup ] [ Return to Tractor Talk Discussion Board ]
Posted by Gerald on January 31, 1999 at 15:19:30:
In Reply to: loader conversion to full hydraulics posted by Kevin on January 31, 1999 at 14:33:19:
If the front pump lifts rapidly enough its big enough. Going to double acting cylinders won't need more pump capacity, but a new valve. Probably the valve should be a dual valve for double acting cylinders, probably open center. You want the same stroke and diameter on the cylinders for lift as you already have and you will have to work out the bucket cylinder(s) according to their location. CT, TSC, Northern, Baum Iron, all carry suitable parts at varying prices. Gerald
Follow Ups: