JD 3050 remote hyd levers

moxyman

New User
Can anyone show me where the remote levers should be positioned to work a double acting ram on my log splitter also which holes
to connect the pipes at the back TIA
 

Welcome to YT
I presume your log splitter has an independent hyd control valve. If that's correct then for tractor hyd system to operate correctly LS valve needs to be configured for closed-center hyd system. Some hyd valves are built to accept a conversion plug to change valve from open center to closed center configuration.

The side of tractor breakaway coupler that splitter control valve pressure hose is attached will determine which direction tractor SCV control lever needs moved. IIRC splitter valve pressure hose in RH breakaway will require tractor valve control lever moved rearward.
 

We sell tractor parts! We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today.