I have a John Deere 401D utility that keeps shutting off. Replaced fuel filter and fuel pump, runs for few minutes then shuts off, anyone have know what the problem could be?
 
If it is a diesel, the governor ring in the injection pump is coming apart clogging the return. Loosen the 2screws holding the timing cover so it leaks alittle fuel and see if the tractor continues to run. If so, the injection pump needs to be rebuilt.
 