I have a JD 1530 that was inherited. It had a 48 series FEL [front end loader], but has never worked.
I am trying to get it functional before hay season arrives in TN.
Currently the 3pt works great no matter how heavy the attachment is. When I connect the lines to the FEL (supply line tees into line after the pressure control valve, return is plumbed into transmission housing top right above ankle.) The FEL shutters to raise and if any attachment is on the 3pt it fails to raise unless I max out a cylinder on the FEL (bucket or arms).
I also have a ported filter cover coming next week to see if this helps any at all. Just having a hard time processing what could be causing the 3pt issues after the FEL is attached.
I am trying to get it functional before hay season arrives in TN.
Currently the 3pt works great no matter how heavy the attachment is. When I connect the lines to the FEL (supply line tees into line after the pressure control valve, return is plumbed into transmission housing top right above ankle.) The FEL shutters to raise and if any attachment is on the 3pt it fails to raise unless I max out a cylinder on the FEL (bucket or arms).
I also have a ported filter cover coming next week to see if this helps any at all. Just having a hard time processing what could be causing the 3pt issues after the FEL is attached.