Anyone have a light on the charging system that they can't get to shut off? Background: 2000 JD LX255, Kohler CV15S-41571. Good battery. Checked and cleaned posts. Checked and cleaned terminals on voltage regulator and wire connector. With the engine running, 14.4 volts with a good digital meter. Swapped regulators, 13.46 volts. Put original regulator back on, 14.4 volts. Voltage with tractor off, 12.46 volts. It appears the charging system is working, but the light stays on. I cleaned all the wire connectors I could find and applied dielectric grease on all of them. I just got this tractor a couple weeks ago, so I don't know the history of it. John Deere service ADVISOR makes no mention of the light, that we could find. A check of the stator output voltage at idle is supposed to be 26 volts AC, and that checks out OK. Any ideas? I've about run out.