Went out and started the tractor yesterday, and the little AMP light came on. Battery voltage with the tractor running is 12.4, but I'm having problems checking my generator output.
When I put my negative meter lead on the negative battery terminal, and touch the positive meter lead to either of the two poles on the generator, I get 0. When I stick the negative meter lead on the positive battery terminal, and the positive meter lead on either of the generator posts, I get -12.4
Where do I need to check next, or what should I be looking for? Thanks!
When I put my negative meter lead on the negative battery terminal, and touch the positive meter lead to either of the two poles on the generator, I get 0. When I stick the negative meter lead on the positive battery terminal, and the positive meter lead on either of the generator posts, I get -12.4
Where do I need to check next, or what should I be looking for? Thanks!