Welcome! Please use the navigational links to explore our website.
PartsASAP LogoCompany Logo Auction Link (800) 853-2651

Shop Now

   Allis Chalmers Case Farmall IH Ford 8N,9N,2N Ford
   Ferguson John Deere Massey Ferguson Minn. Moline Oliver

Discussion Forum
:

Charging Voltage of D-17 generator

Welcome Guest, Log in or Register
Author  [Modern View]
Flewster

08-25-2008 20:01:53




Report to Moderator

Ok I just installed new voltage regulator and two 6v bats in series just as designed for my D-17..... .checked and ohm'ed all wiring..... all good..... ..voltage showed 12.71 after installed..... ...cranked and started motor and read voltage as 12.49..... ...turned on lights then went and did work with tractor for about an hour.....shut off lights and returned to shop..... .shut down and voltage reads 12.70..... ..I put new amp meter in and it never went to the pos side as far as I could tell..... ..showed neg draw when lights were on and of course I could not watch it all the time..... ..... .other than waiting to see if bats die after several starts how do I know that the generator is working properly???..... ...

[Log in to Reply]   [No Email]
El Toro

08-26-2008 08:55:53




Report to Moderator
 Re: Charging Voltage of D-17 generator in reply to Flewster, 08-25-2008 20:01:53  
Should be around 14 volts with the engine at 1/2
throttle or better. Hal



[Log in to Reply]  [No Email]
Flewster

08-26-2008 08:50:57




Report to Moderator
 Re: Charging Voltage of D-17 generator in reply to Ed Hodge, 08-25-2008 20:01:53  

John T said: (quoted from post at 10:48:24 08/26/08) You Polarize NOT running BEFORE you start it to avoid possible VR damage. The other tests in my procedure like field grounding and VR cutout relay by pass are when RUNNING. Motor test, of course, is when NOT running
John T


Thanks..... ..my only concern now is that I damaged my new VR by running it so long with out polorizing the generator..... .guees I will see when I get home tonight..... ....THANKS AGAIN!!!

[Log in to Reply]  [No Email]
Flewster

08-26-2008 06:50:58




Report to Moderator
 Re: Charging Voltage of D-17 generator in reply to Flewster, 08-25-2008 20:01:53  
OK I think I got this figured out..... you do the polorization when the tractor is off..... ..then all the other testing when it is running..... ...is this correct?

Sorry just really new at all this generator stuff!!



[Log in to Reply]  [No Email]
Flewster

08-26-2008 06:34:21




Report to Moderator
 Re: Charging Voltage of D-17 generator in reply to Flewster, 08-25-2008 20:01:53  
Thank you for the information..... ....I was looking at archives because i remembered your post that I saw from long time back and I printed it off then came here and you posted it again..... .....THANK YOU!!!!!..... ....I will try this this evening when i get home and let you know the results..... .sucks when you buy a piece of equipment and the previous owner or owners have did things to keep it running or did not kow what they were doing..... ..... this had an automotive bat in it hooked up NEG ground and there were wires clipped underneath..... ....so I have gotten it back to the 2 6v and POS grounded, new regulator so now I guess I need to polorize the generator..... ..... I was looking at your steps and it does not say with engine running or not..... ...do you do the grounding with running or not running engine?

[Log in to Reply]  [No Email]
John T

08-26-2008 08:48:24




Report to Moderator
 Re: Charging Voltage of D-17 generator in reply to Flewster, 08-26-2008 06:34:21  
You Polarize NOT running BEFORE you start it to avoid possible VR damage. The other tests in my procedure like field grounding and VR cutout relay by pass are when RUNNING. Motor test, of course, is when NOT running

John T



[Log in to Reply]  [No Email]
John T

08-26-2008 06:20:45




Report to Moderator
 Re: Charging Voltage of D-17 generator in reply to Flewster, 08-25-2008 20:01:53  
Flew, it depends on the voltmeter quality/accuracy and the batery condition but Id expect something like 12.6 volts setting but around 13 to 14 and a lil better whens shes running at fast RPM IFFFFF FF the charging system is working????? ? Sure the new ammetr is wired correct??? theres usually but ONE wire on the Supply terminal (to battery/starter) while its other Load terminal wires to BAT on the Voltage Regulator plus feeds hot battery voltage to loads like lights n ignition (switches)

I have a URL Link to my Charging Troubleshooting Procedure which covers most all problems n describes how to polarize, if you work through it the cause can likely be determined.....

John T

[Log in to Reply]  [No Email]
Flewster

08-25-2008 20:20:28




Report to Moderator
 Re: Charging Voltage of D-17 generator in reply to Flewster, 08-25-2008 20:01:53  
how do you polorize the generator? Book did not say anything about that.



[Log in to Reply]  [No Email]
Bob

08-25-2008 20:17:56




Report to Moderator
 Re: Charging Voltage of D-17 generator in reply to Flewster, 08-25-2008 20:01:53  
Did you polarize the generator?

You should be seeing a charging voltage of probably 13.8 to 14.5 Volts.



[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.