My brother bought a new one a few years ago, had same problem took it back, got another new one, worked fine maybe you got a bad one. Someone else will have more suggestions.
 
Check for an inline fuse in on eng wiring,briggs may have installed fuse in alt output lead,after that check owners manual for a wiring diagram,equipment mfg may have installed a fuse in wiring harness for alt output,also check for loose/bad plug in connectors in wiring harness & loose/bad connector/connections at ign sw.

If no blown fuse found & all connectors/connections good,tight & clean,disconnect output DC output lead on regulator,run eng 3/4-full throttle,measure output voltage,should be 13-14.5v DC,if no output from reg,disconnect stator leads from reg & measure AC voltage output from stator,this voltage may be between 20 & 40v AC depending on amp output of stator as briggs used four different amp output rateing stators for regulated output charging systems on vanguard eng,you may need a service manual for eng to test/troubleshoot & id alt stator,the AC output voltage on each stator is different depending on amp output of same.Possible causes of no AC output from stator,stator bad or missing/broken magnets in flywheel.
 