Topic: Grounding a metal building ?
[Return to Forum]
| Author |
[Modern View]
|
| jCarroll
10-05-2012 04:49:50
75.22.113.218
|
I'm having a metal skin shed built (post and beam with metal siding and roof). Will eventually have electric service.Should the building be grounded? How do lightning rods fit into this issue? |
|
|
| John T
10-05-2012 14:32:56
216.249.82.117
|
|
Re: Grounding a metal building ? in reply to jCarroll, 10-05-2012 04:49:50
|
|
| | Its been yearssssssss since I was an electrical design engineer, but way back when there wasnt any requirement the outer metal skin of a pole barn shop etc be grounded, but it wouldnt hurt if you wished to do so. Problem is theres half A$$ "grounding" like if you bonded to one sheet of metal and relied on all the screws n nails for an effective current path among all the panels orrrrrrrrrrr run a braided copper wire around the building and bond to each n every piece which I doubt youre interested in doing.... ITS THE ELECTRICAL SERVICE THAT REQUIRES PROPER GROUNDING instead of the metal skin sheets. Sure you can install lightning rod protection if you wish but again its not a requirement Im aware of and Id worry less about the metal shop then a frame home as far as fire is concerned. John T |
|
|
| Bill46
10-05-2012 08:18:46
69.174.87.108
|
|
Re: Grounding a metal building ? in reply to jCarroll, 10-05-2012 04:49:50
|
|
| For a single circuit bldg, if the sysyem is grounded...you need not have one. If you have more than 1 circuit, you must have at least 10ft of metal waterline in the ground to attatch to or an 8ft ground rod. The ground rod wire must be at least as as large as the feeder wires to the bldg. |
|
|
| buickanddeere
10-05-2012 12:37:44
184.151.61.251
|
|
Re: Grounding a metal building ? in reply to Bill46, 10-05-2012 08:18:46
|
|
| What code book are you looking at ? |
|
|
| Bill46
10-08-2012 04:27:54
69.174.87.108
|
|
Re: Grounding a metal building ? in reply to buickanddeere, 10-05-2012 12:37:44
|
|
| Went to the shop and looked it up in the new code. They changed the rules. If it is a new building, you must have a piece of re-bar in the concrete grounded to the box and the building also. Then, the boulding and the box must be grounded to the ground rod. NEC 250.52. |
|
|
| Ted in NE-OH
10-05-2012 07:53:27
173.189.169.175
|
|
Re: Grounding a metal building ? in reply to jCarroll, 10-05-2012 04:49:50
|
|
| Lightning rods depends on how frequently you get lightning storms. |
|
|
| buickanddeere
10-05-2012 06:29:15
184.151.61.6
|
|
Re: Grounding a metal building ? in reply to jCarroll, 10-05-2012 04:49:50
|
|
| Yes, no and maybe. If the door frames are metal, it's not unusual to see those grounded. If there is any livestock in the future. Then the water system and metal stalls should all be bonded together. Running four wires to the shed panel instead of a three wire will prevent a lot of problems with tingle voltage. This would be the time to deep bury a couple of ground plates 10 ft deep and 8 ft each side of the shed panel. Run #6 copper up for the connection. |
|
|
| David G
10-05-2012 05:41:48
205.215.206.18
|
|
Re: Grounding a metal building ? in reply to jCarroll, 10-05-2012 04:49:50
|
|
| I am not aware of any regulation regarding this. It will be interesting to hear other responses. Any electrical outlet or device should be grounded. |
|
|
[Options]
[Printer Friendly]
[Return to Forum]
[Add a Reply]
| Same-Day Shipping! Most of our stocked parts ship the same day you order (M-F). Expedited shipping available, just call! Most prices for parts and manuals are below our competitors. Compare our super low shipping rates! We have the parts you need to repair your tractor. We are a Company you can trust and have generous return policies! Shop Online Today or call our friendly sales staff toll free (800) 853-2651. [ More Info ] |
Home
| Forums
Copyright © 1997-2013 Yesterday's Tractor Co. All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V. Yesterday's Tractors - Antique Tractor Headquarters |
About this site - Yesterday's Tractors is your one-stop source for antique tractors. If you are interested in older tractors you've come to the right place! Join more than 275,000 other classic tractor enthusiasts from all over the globe. We have many resources for antique tractor enthusiasts available including photos, classified ads, more than 24 tractor discussion forums, a show guide, values, specs and much more. Bookmark this site and come back often. Thanks for stopping by! Feel free to use our feedback form to send us your comments, suggestions and ideas.
|
|
|