Merry Christmas to all...I hope all your holidays are full of joy.
I've been working on a 50 front mount that was converted when we bought it. The motor was locked and it didn't run. Just finished the motor and have no spark.
I replaced the wiring per JMORs diagram for a Delco 1 wire alt, minus the lights. I have 12 volts to coil with key on, 0 key off. 12 volts to points with key on and 12 volts to breaker plate with points closed. 12 volts to secondary with points open about 2 with points closed.
I have tried two set of points and two condensers with no change. The ballast glows red hot with points closed, but not with points open. Im at a loss, any help is appreciated.
I've been working on a 50 front mount that was converted when we bought it. The motor was locked and it didn't run. Just finished the motor and have no spark.
I replaced the wiring per JMORs diagram for a Delco 1 wire alt, minus the lights. I have 12 volts to coil with key on, 0 key off. 12 volts to points with key on and 12 volts to breaker plate with points closed. 12 volts to secondary with points open about 2 with points closed.
I have tried two set of points and two condensers with no change. The ballast glows red hot with points closed, but not with points open. Im at a loss, any help is appreciated.