I need to replace my front hyd pump. My old pump is the cessna 20644 which I measured to have 1.9776 CIR. I think the pressure is rated at 3000 PSI but I'm not sure about that. My tractor is a mf 205 industrial, which has a loader, 3pt rams and also a backhoe attachment which I don't have...I have just the loader and 3pt rams.
What if I replaced this pump with a 1.95 CIR with a pressure of 2300 PSI MAX? This pump is considerably less $.
Would my loader still lift a bucket full of dirt OK?
What if I replaced this pump with a 1.95 CIR with a pressure of 2300 PSI MAX? This pump is considerably less $.
Would my loader still lift a bucket full of dirt OK?