I went to load the tare-down tractor for the FENA expo this weekend and she won"t start.
I want to pin point this as I do not have time to shot gut this or that.
What I know:
TO-20 Cont. z120.
Fuel flow ok
Coil showed 2.2 ohms across the terminals that drifted down to 1.9 over 5 to 10 seconds.
No Spark from center lead of coil (disconnected from center of cap then placed next to ground.
I removed the cap and no spark across the points.
With points open I get 6V at the coil. 6 V at the distributor. (and near side of points.) nothing opposite side of points obviously.
When closed Voltage drops to .3V or so.
That"s what I know. Where to look next?
Jeff
I want to pin point this as I do not have time to shot gut this or that.
What I know:
TO-20 Cont. z120.
Fuel flow ok
Coil showed 2.2 ohms across the terminals that drifted down to 1.9 over 5 to 10 seconds.
No Spark from center lead of coil (disconnected from center of cap then placed next to ground.
I removed the cap and no spark across the points.
With points open I get 6V at the coil. 6 V at the distributor. (and near side of points.) nothing opposite side of points obviously.
When closed Voltage drops to .3V or so.
That"s what I know. Where to look next?
Jeff