Has anyone gotten a new tube that connects to the hyd pump to the tractor housing. The reason I am ask this because the seal that is on the new tube has a metal housing instead of the old seal was basically all rubber. I tried to install the new tube into the housing and like any modern day seal it didn't slip right in, it needs to be press in. In the shop manual it states that the lip of the seal needs to face toward the pump. With this new seal design thinking I have to take the seal, hammer into the house with the seal lip facing the pump and install the tube on the pump. Then here is my concern, trying to get the tube into the seal without damaging the seal. Should I install the seal the other way?