Case 580 C Backhoe instruments

Plowboy 193

New User
I have a Case 580 C backhoe, this is the problem, on the instrument panel, the water temp, trans. oil temp, and the fuel guage all quit at the same time. Seems to me there must be a common connection to the three guages. Any help with this situation will be much appreciated.
 
Check none of the circuit breakers have popped, all the gauges are fed by a common power supply when the key is switched on,ground is made through the respective sender units,where the loom connects to the back of the instrument panel there is a multi plug,the contacts are a likely source of the problem,unplug and replug it a few times and see if the gauges work again,if that does not work you will have to find the wire coming from the ignition switch and test its continuity to the multi plug,if thats good check the circuit on the board for a break.
Good luck
AJ
 