thomaskd44
Member
As I reported; the dozer crawler is operating. There are a few things of concern. One; I am not sure of the firing order. I have 1 -staring at the rear of the engine; and 3 -4- 2 -1-3-4-2 I don't know if the one cylinder is supposed to be at the rear or at the front, or if that is the correct firing order? The other concern, is the first cylinder at the rear. When the engine is operating, there is white smoke out the exhaust. When I loosen the fitting to the injector; there is no change in the R.P. M. and the white smoke vanishes. Connecting the fitting, the white smoke begins. So, I am confused as; is this because of firing order, or valve problem? Any help? Secondly, at the injector pump, there is a cap. Taking it off I see only a metal piece. Does diesel go into this opening?; is it suppose to be full? Something must go there for the cap being there. Any help is appreciative.
Tho
Tho